Results 11 to 20 of about 43 (43)
It is proposed the definition of the installed (rational) refrigeration capacity of a waste heat-recovery absorption-ejector chiller that utilizes the heat of the exhaust gases of a gas turbine unite to cool the air at the inlet.
Богдан Сергійович Портной
doaj +1 more source
It is justified the necessity of taking into consideration changes in thermal loads on the air conditioning system (heat and moisture treatment of air by cooling it with decreasing temperature and moisture content) in accordance with the current climatic
Микола Іванович Радченко +4 more
doaj +1 more source
The processes of gas turbine unit two-stage intake air cooling by absorption lithium-bromide chiller as a high temperature cooling stage to the temperature of about 15 °C and by refrigerant ejector chiller as a low temperature cooling stage to the ...
Андрій Миколайович Радченко +3 more
doaj +1 more source
Підвищення енергоефективності багатозональних VRF систем кондиціювання повітря
Визначено енергозберігаючі заходи підвищення енергоефективності в області кондиціювання за допомогою методів математичного моделювання схемно-технічних рішень і режимів роботи обладнання систем кондиціювання громадських об'єктів при використанні сучасних
Н. В. Жихаpєва +2 more
doaj +1 more source
The air conditioning processes (heat-humidity treatment) at the inlet of energy units by heat-energized refrigeration mechanisms with heat removal cooling towers of the cooling system are studied on the example of a gas turbine unit.
Андрій Миколайович Радченко +3 more
doaj +1 more source
The results of calculation of two stage gas turbine unit intake air cooling processes with previous cooling by absorption lithium-bromide chiller and deep cooling by ejector chiller are presented.
Андрей Николаевич Радченко +3 more
doaj +1 more source
Cooling the air at the inlet of gas turbine units by utilizing the exhaust gas waste heat in the combined absorption-ejector chiller with absorption lithium-bromide chiller as a gas turbine unit and refrigerant ejector chiller as a low temperature ...
Андрей Николаевич Радченко
doaj +1 more source
The heat-humidity processes of gas turbine unit intake air deep cooling to the temperature of 10 °C and lower with the use of refrigerant boiling at the temperature of about 4-6 °C as a coolant and the ejector chiller utilizing the turbine exhaust gas ...
Андрій Миколайович Радченко +4 more
doaj +1 more source
Оптимізація енергоефективності будівлі багатопрофільного медичного центру
Мета. Підвищення теплової ефективності будівлі багатопрофільного медичного центру шляхом оптимізації архітектурно-планувальних рішень, врахування кліматичних умов та вдосконалення параметрів інженерних систем. Будівля розглядається як єдина енергосистема,
A. V. Radkevych +2 more
doaj +1 more source
The heat-humidity processes of gas turbine unit intake air cooling to the temperature of above 15 °C with the use of a cold water at the temperature of about 10 °C as a coolant and the absorption lithium-bromide chiller utilizing the turbine exhaust gas ...
Андрій Миколайович Радченко +4 more
doaj +1 more source