Results 21 to 30 of about 1,917 (152)

Effects of Mn on the microstructure morphology and phase transformation of medium manganese wear resistant steel [PDF]

open access: yes, 2016
The effects of Mn on the microstructure morphology,phase transformation and mechanical properties of medium manganese wear resistant steel were investigated by DIL805 A thermal analyzer,scanning electron microscopy,electron back-scattered diffraction ...
CHE Ying-jian   +4 more
core   +1 more source

Original experimental platform system and application of underground coal mine reservoirs [PDF]

open access: yes
Coal is the main energy source in China, and the western region in China is the main coal production area. The protection and utilization of coal mine water is the major technical challenge in the coal mining. The coal green mining research team of China
Baoyang WU   +12 more
core   +1 more source

基于模拟负载的特高压换流阀MVU冲击电压试验方法探讨

open access: yesGaoya dianqi, 2017
特高压直流换流阀多重阀单元(MVU)冲击电压试验为型式试验的一部分,四重阀的MVU冲击试验具有试验回路大、试品数量多、试验成本高等不足。为解决上述问题,国内外学者研究设计了模拟负载,并提出基于模拟负载的MVU冲击试验方法。文中对采用该方法得到的试验数据进行分析,得出如下结论:基于模拟负载的MVU操作冲击试验科学可靠;基于模拟负载的MVU雷电冲击试验,在阀两侧并联电容可改善模拟负载电压波形;基于模拟负载的MVU冲击电压试验,需进行总试验电压及模拟负载电压的差值运算,防止阀承受过高电压导致晶闸管级损坏 ...
贾涛   +6 more
doaj  

基于传递函数法的变压器感应式振荡操作冲击电压试验故障诊断技术研究

open access: yesGaoya dianqi, 2020
采用感应式振荡型操作冲击电压对变压器进行现场冲击耐压试验具有效率高、易于调波、试验设备体积小等优点。为了研究变压器匝间短路故障在感应式振荡操作冲击电压下的电压传递函数特性,构建了感应式振荡操作冲击电压下变压器的电压传递函数,建立了模拟变压器匝间短路的试验模型,并以该模型为试验对象搭建试验系统进行试验。通过分析试验数据后发现,存在匝间短路故障的变压器在感应式振荡操作冲击电压作用下,其电压传递函数与无故障时相比,极值点所在的频率升高,极值点的幅值降低。短路故障越严重,极值点的变化趋势越明显 ...
孙文星   +5 more
doaj  

Collaborative Chinese Text Recognition with Personalized Federated Learning

open access: yes, 2023
In Chinese text recognition, to compensate for the insufficient local data and improve the performance of local few-shot character recognition, it is often necessary for one organization to collect a large amount of data from similar organizations ...
Li, Bin   +3 more
core  

GIS对接冲击试验方法及冲击电压波形分析

open access: yesGaoya dianqi, 2017
大容量GIS冲击电压试验电压波形受回路电感影响较大,影响输出波形波前时间,降低冲击试验绝缘缺陷检测的有效性。笔者从冲击试验时电压引入方式入手,基于研制的2 000 kV紧凑型冲击电压发生装置,提出了GIS对接冲击试验方法,开展了145 kV和252 kV GIS对接冲击试验。该方法利用变阻抗转接段和液压升降装置,可将冲击电压发生器电压输出端直接与GIS预留对接口相连,回路紧凑,减小了因高压导线引入的电感,提高了冲击试验波形质量。最后通过仿真软件,分析了当负载电容量较大时 ...
谭向宇, 文韬, 刘轩东, 庞磊
doaj  

试验回路布置对变电站地网冲击特性测试的影响

open access: yesDianci bileiqi, 2020
开展地网冲击特性测试需搭建冲击放电回路,试验回路布置的差异会对地网冲击特性测试产生较大影响。在分析现有接地装置冲击试验系统构成的基础上,搭建试验回路对110 kV变电站地网进行了现场试验,研究了注流点对地网冲击特性的影响,并通过仿真计算研究了回流点对地网冲击特性的影响。试验结果表明,试验回路中注流点、回流点的选择会明显影响地网电位分布和电流的大小。在雷电冲击下地网高电位区域会集中在注流点附近,远离注流点的区域地网电位分布较均匀,注流点附近区域的地网散流变化大,远离注流点区域的地网散流较平均。仿真结果表明,
黄佳瑞   +4 more
doaj  

Calculation of slope stability of fault-containing slopes under the action of cyclic blast vibration [PDF]

open access: yes
In order to accurately quantify and predict the evolution of slope stability of fault-containing slopes under the long-term effect of blasting vibration, and to realize the safe, efficient and sustainable mining of open-pit mines. Taking an open-pit mine
Dong WANG   +3 more
core   +1 more source

特高压变电站1100kV GIS现场冲击耐压试验方法

open access: yesGaoya dianqi, 2017
开展GIS现场冲击耐压试验有利于发现设备运输和现场安装过程中产生的内部缺陷和隐患。浙南站1 100 kV GIS现场冲击耐压试验为世界首次开展,文中介绍了浙南站1 100 kV GIS现场冲击耐压试验参数的确定、试验装置的结构和参数以及等效回路的计算过程,形成了浙南站现场冲击耐压试验方法。使用该试验方案在浙南站成功开展了现场冲击耐压试验,现场试验未发生放电故障,该试验方法将为后续超特高压工程开展相关试验提供技术依据和示范作用。
程鹏   +8 more
doaj  

Simulation and experimental analysis of MEMS threshold adjustable switch [PDF]

open access: yes, 2016
微系统(MEMS)阈值可调开关是一种适用于弹药类型的通用碰炸开关,靠捕捉碰撞目标时的前冲惯性力而闭合。此开关除了受惯性力和静电力之外,还受到可动电极和驱动电极之间由于空气阻力而产生很大的阻尼力的影响。利用Coventor wave软件中的Saber系统仿真法,对设计的开关结构进行瞬态特性分析,仿真结果表明:开关在不同加速度信号下,阈值加速度与电压基本上呈反比关系,且随着阈值加速度的增大,电压减小。对加工的开关样件进行实验检测,实验结果表明开关可以实现阈值可调。MEMS threshold ...
刘凤丽, 许马会, 郭航
core  