Results 21 to 30 of about 753,851 (138)

Rapid Removal of Binder From Spent Lithium‐Ion Batteries by Microwave Radiation for Enhanced Flotation Separation of Anode and Cathode Materials

open access: yesRare Metals, Volume 45, Issue 9, September 2026.
ABSTRACT Achieving rapid and selective separation of anode and cathode materials remains a critical challenge in the recycling of spent lithium‐ion batteries. This study develops a microwave‐enhanced flotation strategy for the efficient recovery of cathode and anode materials.
Peiyuan Ye   +5 more
wiley   +1 more source

雷击交流侧同塔双回线路时换流站过电压特性

open access: yesDianci bileiqi, 2020
超高压电网多采用同塔双回或多回线路,由于杆塔较高,遭受雷击时可能造成多回线路闪络。依托某换流站500 kV交流侧系统,利用EMTP/ATP建立电站雷电侵入波过电压计算模型,研究换流站交流侧同塔双回线路遭受雷击时站内设备上过电压特性以及与单回线路的区别。结果表明:雷击同塔双回线路杆塔时,在两回线路均闪络的情况下,换流站设备上反击侵入波过电压在双线运行方式下幅值远高于单线运行方式,且过电压最大值一般是在雷击进线段第二基杆塔TW2时出现,反击过电压特性与雷击单回线路差异较大 ...
周姣, 陈小月
doaj  

Global Surgery at the Frontlines of Conflict Zones: Role of Health Diplomacy in the Provision of On‐Site Surgical Care to Children

open access: yesWorld Medical &Health Policy, Volume 18, Issue 3, September 2026.
ABSTRACT Confrontational violence still puts catastrophic burdens on children, with 2024 being the highest recorded levels of displacement, malnutrition, injury, and deprivation in contemporary humanitarian history. Children's surgical care is still grossly underrepresented in health responses worldwide in the prevention of avoidable deaths and long ...
Gaurav Chanderprakash Mittal   +4 more
wiley   +1 more source

回旋流型流化床垃圾焚烧炉及其冷态空流场的数值分析

open access: yes, 1994
从固体废弃物减量化、无害化与资源化处置的要求出发;本文探讨了回旋流型流化床技术及其在城市垃圾处理中的应用问题。分析了回旋流型流化床垃圾焚烧炉的流态及炉内冷态空流场的特性 ...
田文栋   +3 more
core   +2 more sources

利用振荡回路进行高压限流熔断器试验的可行性分析

open access: yesGaoya dianqi, 1996
介绍了用振荡回路作限流熔断器开断能力试验的可行性。分析了限流熔断器在开断短路电流过程中的物理现象。推荐了一种作限流熔断器试验的振荡回路,并例举了限流熔断器在振荡回路上作开断短路电流试验的结果。
王季梅
doaj  

Development and Psychometric Validation of the Chinese Online Disinhibition Scale for Adolescents

open access: yesPsyCh Journal, Volume 15, Issue 4, August 2026.
ABSTRACT Online disinhibition significantly influences adolescents' communication and behaviors in digital environments, yet culturally adapted measurement tools remain limited in China. This study aimed to develop and validate a Chinese version of the Online Disinhibition Scale (ODS‐C) based on Suler's (2004) theoretical framework.
Ziyao Zhou, Yujun Ma, Lin Wang
wiley   +1 more source

Ophthalmic artery Doppler as potential surrogate marker of angiogenic imbalance in near‐term pregnancy

open access: yesUltrasound in Obstetrics &Gynecology, Volume 68, Issue 2, Page 211-219, August 2026.
ABSTRACT Objectives First, to evaluate whether the ratio of soluble fms‐like tyrosine kinase‐1 to placental growth factor (sFlt‐1/PlGF) is associated with hemodynamic changes in ophthalmic artery (OA) Doppler in near‐term pregnancy. Second, to assess the performance of OA Doppler to rule in and rule out angiogenic factor imbalance.
M. F. Tinajero   +7 more
wiley   +1 more source

计及回流电流和分流电流影响的接地参数分析计算

open access: yesDianci bileiqi, 2016
在以往的接地参数计算中,直接将站内和站外不对称短路时的最大入地短路电流从接地网边角注入来计算各个接地参数,而忽略了短路过程中形成的回流电流和分流电流,这造成某些接地参数计算误差较大。本文以某电站的短路电流分布为例,计算分析了回流电流和分流电流对接地参数计算的影响,并研究了在计及回流电流和分流电流的情况下各个敏感因素对接地参数的影响。研究表明:计及回流电流和分流电流后,GPR会增大一定的幅度,但电位梯度和网内电位差相比只考虑入地短路电流时会增大很多,地表电位不均衡程度大大增大,接触电势和跨步电势也相应增大。
郭婷婷, 文习山, 杨琪
doaj  

Farm‐Scale Recharge Pits for Improving Local Groundwater Availability: Insights From a Hardrock Watershed in Rajasthan, India

open access: yesWorld Water Policy, Volume 12, Issue 3, August 2026.
ABSTRACT Groundwater depletion is a major challenge in semiarid, hard‐rock regions where irrigation demands often exceed natural recharge. This study evaluates the effectiveness of farm‐scale recharge pits as a local, supplementary, and community‐managed groundwater recharge solution in the Dharta catchment of Rajasthan, India. Alongside check dams and
Prahlad Soni   +4 more
wiley   +1 more source

回流次数对间歇厌氧-好氧反应器处理效果的影响

open access: yesGongye shui chuli, 2015
研究了回流次数对间歇厌氧-好氧反应器处理效果的影响。结果表明,回流对硝化过程没有明显影响,3种条件下NH4+-N去除率均能达98%以上。而在回流次数较少的情况下,反硝化过程易受进水负荷的影响。增加回流次数有利于反硝化电子受体(NO3--N)的转移,并充分利用进水中的有机物进行反硝化过程,提高脱氮率。同时,反硝化速率也随回流次数的增加而增加。
唐嘉陵   +3 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy