Results 101 to 110 of about 1,157 (159)
桩–筏–土体系的地震软化行为及ABAQUS模拟研究 [PDF]
通过开展离心机动力试验,充分揭示在地震荷载的持续作用下,土体将发生一定程度的软化,表现为周期的持续增大;然而基础(筏板)周期和桩身弯矩包络图几乎不发生改变,说明整个桩–筏结构在地震作用下的行为不会类似于土体发生软化(恶化的现象),而是能持续保持稳定,其动力行为主要取决于自身特性如桩身刚度和上部结构传递给筏板的荷载水平(惯性)等,同时土体的动力软化效应对桩–筏结构的影响很小。为了验证试验结果的正确性和合理性,采用ABAQUS 6.9程序对试验结果进行计算分析 ...
许强, 马亢
core
Characterisation of the temporal sequence of geomagnetic fluctuation of Xinmocun landslide [PDF]
Selecting an appropriate index is essential for the scientific and effective early warning of landslides. To explore the potential use of geomagnetic fluctuation signals as an early warning index for landslides, this study investigates the ...
Chieh-hung Chen +5 more
core +1 more source
近年来,复合支柱绝缘类设备逐渐在特高压变电站中得到应用,然而其弹性模量相对瓷质设备更小,使得设备刚度更低、体系更柔。为研究其耦合体系抗震性能以及对地震强度等因素的影响,文中首先介绍了所采用的结构动力响应分析理论,进而采用Abaqus软件建立了管母耦联的±800 kV复合双支柱绝缘子设备体系,该体系两端为一端固定一端滑动。随后,分析并比较该体系不同方向的模态振型,基于所建立的仿真模型进行动力响应分析,并分别考虑了地震强度、频谱及多维地震耦合对于该耦联体系地震响应的影响。结果表明 ...
李强, 张长虹, 余荣兴, 陈超泉
doaj
高压电气设备地震易损性极高,提升高压变电站电气设备抗震能力成为设备厂家和运行单位的关键技术指标。首先,以高压瓷柱式电气设备为研究对象,建立了设备多质点理论模型的运动方程和高压电气设备理论模型刚度矩阵构建方法,开展了减震设计及其减震元件参数优化分析,研究了减震元件参数对设备减震效果的影响。其次,定义了设备减震元件的刚度比、名义阻尼比和结构响应的减震比等设计参数,以设备地震响应的减震比为优化目标,确定了减震元件主要设计参数的合理取值范围。最后,建立了一台220 kV SF6断路器有限元模型 ...
程义凯, 曹枚根, 郑翀, 夏祥泰
doaj
[Impact of outpatient services utilization of heart failure patients on hospitalization rate and its threshold effect: Taking patients with Urban Employee Basic Medical Insurance in Zhejiang Province as an example]. [PDF]
Zhang H, Jing R, Wang J, Fang H.
europepmc +1 more source
Case studies of liquefaction induced damages to two pile supported river bridges in China
Pile supported river bridges still continue to collapse after most major earthquakes in the event of liquefaction. The identified failure mechanisms of piles in liquefied soil are: bending failure due to the inertial loads of the superstructure and ...
Bhattacharya, S, Mohanty, P
core +1 more source
由于大跨空间结构竖向振动问题突出,水平隔震支座难以有效控制结构的竖向地震响应。将摩擦摆水平隔震支座和空气弹簧-摩擦摆三维隔震支座应用于大跨度钢桁架中,分析钢桁架水平隔震结构和三维隔震结构的隔震控制效果。结果表明,水平隔震和三维隔震均延长了结构自振周期,隔震后一阶振型为上部桁架结构沿水平方向的整体平动。时程分析显示,在普通地震动、近断层脉冲型地震动和远场长周期地震动作用下,水平隔震支座对桁架水平和竖向节点峰值加速度的平均隔震率分别为43.4%和9.2 ...
韩庆华, 景铭, 芦燕, 刘铭劼
doaj
[Progresses on temporal interference electromagnetic stimulation for non-invasive deep brain function modulation]. [PDF]
Zhou T, Yu P, Xu Y.
europepmc +1 more source
近年来,强震对于电力系统的正常运行造成严重威胁,因此对电力系统关键结构进行抗震分析和评估尤为重要。文中针对某220 kV高压输电线路中实际输电塔及其塔线耦联体系进行抗震性能评估。首先,采用Abaqus软件建立塔体及塔线耦联体系有限元模型,分析其动力性能、塔腿杆件应力、节点位移及加速度响应。通过对比单塔和塔线体系的动力性能和响应峰值,获得导线耦联对输电塔的动力影响。结果表明:耦联体系中输电塔的基频要低于单塔模型6%~9%左右,导、地线的存在会使得结构基频降低;由于导地线作用 ...
陈艺征 +5 more
doaj
[Simulation analysis of adaptability of large airborne negative pressure isolation cabin to aviation conditions]. [PDF]
Guo L +7 more
europepmc +1 more source