Results 11 to 20 of about 6,539 (91)

Groundwater mapping and locally engaged water governance in a small island terrain: Case study of Karainagar island, Northern Sri Lanka

open access: yesWorld Water Policy, Volume 9, Issue 3, Page 456-480, August 2023., 2023
Abstract Groundwater is a vital resource under threat in island communities. Karainagar, a 22 km2 island, is one of seven islands off the coast of Jaffna in Northern Sri Lanka, with its population of just about 11,000 persons, experiences seasonal water shortage, and salinity in groundwater as twin threats impacting on their lives.
Inthirakumaran Karthiga   +3 more
wiley   +1 more source

MMC celebrating 6 years of experience and expansion 庆祝MMC六年的经验和壮大

open access: yes, 2022
Journal of Diabetes, Volume 14, Issue 5, Page 356-357, May 2022.
Itamar Raz
wiley   +1 more source

International clinical practice recommendations on the definition, diagnosis, assessment, intervention, and psychosocial aspects of developmental coordination disorder – Chinese (Mandarin) translation

open access: yesDevelopmental Medicine &Child Neurology, Volume 61, Issue 3, Page E1-E35, March 2019., 2019
目的 本国际临床指南由欧洲残疾儿童学会(the European Academy of Childhood Disability,EACD)牵头制定,旨在解决发育性协调障碍(developmental coordination disorder,DCD)的定义、诊断、评估、干预以及与社会心理方面的临床应用关键问题。 方法 本指南针对五个领域的关键问题,通过文献综述和专家团队的正式讨论达成共识。为保证指南的循证基础,以“机制”、“评估”和“干预”为检索词, 对2012年更新以来提出的最新建议以及新增的“社会心理问题”和“青少年/成人”为检索词进行检索。根据牛津大学循证医学中心证据等级 (证据水平 [level of evidence, LOE]1–4) 将结果进行分类,最终转化为指南建议。并由国际 ...
Jing Hua   +6 more
wiley   +1 more source

广东地区高温发热线路棒形复合绝缘子劣化特性

open access: yesGaoya dianqi, 2020
为了揭示高温发热的线路棒形复合绝缘子的劣化特性,文中对广东电网江门供电局某220 kV故障绝缘子开展了研究。观察了该支绝缘子的外观形貌,在带电状态下进行红外、紫外检测。之后进行解剖观察,采用现代材料测试方法(SEM、XPS)对比了芯棒劣化处与正常处的材料特性,使用宽频介电谱仪对比测试了劣化处与正常处芯棒短样的电气参数。试验和解剖结果发现,该绝缘子护套表面有击穿孔,加压温升严重、外部有微弱放电。内部交界面处芯棒表面劣化已经从高压端延伸至中部。材料分析表明界面处芯棒受到了严重的放电破坏,环氧树脂发生裂解 ...
彭向阳, 张中浩, 黄振, 王锐
doaj  

波纹护套高压XLPE电缆缓冲层空气间隙电场分布

open access: yesGaoya dianqi, 2021
近年来高压电缆缓冲层故障频发,可能由波纹护套与缓冲层空气间隙局部电场畸变引起,现有电场仿真研究缺乏对波纹护套压纹深度、节距以及缓冲层阻抗的考虑。文中基于麦克斯韦方程建立了考虑电缆波纹金属护套实际几何结构的数值仿真模型和平滑金属护套电缆的电路计算模型,定量分析了110 kV电缆缓冲层材料电导率和介电常数以及波纹金属护套几何结构对空气间隙电势与电场分布的影响。研究表明,当缓冲层材料电导率在10-6~10-9S/m时,空气间隙电势主要受缓冲层材料电导率的影响;当缓冲层材料电导率小于10-9S/m时 ...
李根, 王航, 周文俊, 周承科
doaj  

柔直用压接型高压IGBT导通压降演化规律研究

open access: yesGaoya dianqi, 2021
MMC子模块中的高压功率器件绝缘栅双极型晶体管(insulated gate bipolar transistor,IGBT)在长期运行工况下逐渐发生热老化,最终导致器件失效。因此,研究IGBT的状态监测技术对于MMC的可靠运行具有重要意义。目前的文献压接型IGBT导通压降演化规律研究较少,文中搭建了压接型IGBT功率循环试验平台,并在功率循环试验过程中同时监测得到不同热老化程度下的器件导通压降和门极电流,利用试验得到的结温与门极电流的线性关系将导通压降归一化到同一结温下,从而剥离结温对导通压降的影响 ...
张健   +5 more
doaj  

PRTV涂料对绝缘子串交流冰闪电压的影响

open access: yesGaoya dianqi, 2008
PRTV涂料具有良好的防污闪性能,但用于防覆冰闪络方面,国内外的相关研究还鲜有报道。根据人工气候室的试验结果,笔者分析了在覆冰期、融冰期覆冰水电导率和串长对涂有PRTV绝缘子串的覆冰闪络电压的影响。通过对涂有和未涂PRTV两种形式绝缘子串的覆冰闪络特性的分析,得出PRTV对于提高覆冰绝缘子闪络电压没有效果,涂PRTV的绝缘子串其冰闪电压约降低10%~15%;PRTV涂层的憎水性引起绝缘子表面覆冰状态发生变化,使得冰层与涂料表面粘附不紧密,内部存在许多微小气隙,容易产生局部放电和局部电弧 ...
杜辕   +5 more
doaj  

用局部表面电导率划分污秽等级

open access: yesDianci bileiqi, 1994
目前我国用等值盐密(ESDD)作为表征电瓷外绝缘污秽度的参量,并用ESDD作为划分污秽等级的定量标准,但ESDD与污闪电压Uf的相关性差,用ESDD表征污秽度,划分污秽等级是不合适的。局部表面电导率γp是表征污秽度比较理想的新参量,本文提出了用γp划分污秽等级的方法。
钱茂华, 崔国顺, 关志成
doaj  

湿污表面直流局部电弧的演变过程

open access: yesDianci bileiqi, 2017
飘弧和弧道在湿污表面沿泄漏距离的延伸是局部电弧演变的主要环节。利用高速摄像机观测了不同极性直流局部电弧在湿污表面的演变过程,并从气体放电理论分析和解释了出现上述现象的原因。观测结果表明,负极性电弧比正极性电弧飘弧更严重,且负极性电弧延伸速率高于正极性电弧;电弧延伸过程中,正极性电弧更容易出现分叉和并列弧道的现象,负极性电弧更易出现尖状的头部。负极性电弧更易飘弧是由于电弧与污层之间的流注更易发展,使负极性电弧和污层之间更易保持良好的导电通道,所以飘弧更易维持,也更严重;正极性电弧端部紧贴污层表面 ...
金巧芳, 李亚伟
doaj  

基于特高频时频分析的GIS盆式绝缘子缺陷分析

open access: yesGaoya dianqi, 2019
为更有效在现场开展GIS局部放电检测,及时准确发现设备内部缺陷,特别是盆式绝缘子局部放电缺陷,文中研究了基于特高频时频定位分析的GIS局部放电综合定位方法。将多通道时延定位法和多通道小波时频分析法联合应用,通过局部放电特高频信号的时域和频谱变化特征,结合设备内部结构、装配工艺等情况,实现GIS局部放电综合精确定位。该方法在某500kV变电站220kV GIS带电检测中进行了应用,精确定位一处盆式绝缘子表面放电缺陷 ...
廖新征   +5 more
doaj  