Application and Prospect of Flexible Transmission and Distribution Technology in Internet Data Center [PDF]

open access: yes, 2023
[Introduction] As an important thrust of China's "new infrastructure", internet data centers have ushered in opportunities for vigorous development and become new areas of energy use, putting forward higher requirements for the power supply level and ...
Deyang CHEN   +7 more
core   +1 more source

Research on Construction Mode of Large-Scale Offshore Wind Power Centralized Transmission [PDF]

open access: yes, 2023
[Introduction] Offshore wind power has become a research hotspot in the development of global wind power. China's offshore wind power is still in its infancy, the current operation mode is not conducive to the large-scale centralized transmission of ...
Ni LI   +3 more
core   +1 more source

机械式高压直流断路器工程应用研究 [PDF]

open access: yes全球能源互联网, 2018
针对柔性直流输电系统直流侧故障快速清除的难题,结合南澳多端柔性直流输电工程的实际生产应用需求,提出了一种新型机械式高压直流断路器拓扑方案,研制出了160 kV超快速机械式高压直流断路器产品,提出了一种采用发电机源提供电流来模拟直流故障的开断试验方法,并完成了双向大电流开断试验,开断电流大于9 kA、开断时间小于5 ms。研究并提出了160 kV机械式高压直流断路器工程应用技术方案,并完成南澳加装高压直流断路器示范工程的现场系统调试 ...
陈名   +7 more
doaj   +1 more source

特高压多端混合直流输电系统启动与故障穿越研究 [PDF]

open access: yes全球能源互联网, 2018
采用常规直流与柔性直流混合的特高压多端直流输电系统是昆柳龙直流工程技术方案之一,对采用全桥和半桥混合拓扑的特高压柔性直流输电换流器充电时的均压问题进行分析,提出了两种不同的充电策略。研究了混合三端直流系统的启停顺控流程和直流线路瞬时故障穿越、重启策略。在RT-LAB中搭建三端混合直流输电系统,连接外部阀控装置进行实时仿真实验,实验结果验证了提出的充电策略的正确性,表明所提出的直流线路故障穿越和重启策略可以很好地实现系统穿越故障,使系统重新进入稳态。此外,在±10.5 kV/60 ...
熊岩   +4 more
doaj   +1 more source

500 kV耦合负压换流型混合式直流断路器原理与研制 [PDF]

open access: yes全球能源互联网, 2018
多端柔性直流系统在分布式能源和直流负荷接入、网络柔性互联、电能质量等方面具有显著优势,成为未来电网的重要发展趋势。为了保证多端柔性直流系统安全稳定可靠运行,需要能够在数毫秒内开断故障电流的直流断路器。本文面向张北±500 kV柔性直流电网示范工程的应用需求,开展了500 kV直流断路器原理研究与样机研制。首先,提出500 kV耦合负压换流型混合式直流断路器系统方案,给出其拓扑结构、工作原理和控制逻辑;进而,设计基于电磁斥力操动机构和电磁缓冲机构的快速机械开关 ...
张翔宇   +7 more
doaj   +1 more source

Research on the Key Parameters and Device Capacity Decoupling Analysis of Full Bridge MMC DC Ice-Melting Device [PDF]

open access: yes, 2023
[Introduction] This article aims to study the issue of the melting capacity and reactive output capacity of the full bridge modular multi-level converter (MMC) type DC (Direct Current) melting ice device under different operating modes.
Rui HE, Xiaogang WU
core   +1 more source

特大型新能源基地面临挑战及未来形态演化分析 [PDF]

open access: yes, 2023
在推动中国新能源高质量跃升式发展背景下,大规模新能源开发、汇集和远距离输送成为新能源建设的重要路径之一,特大型新能源基地成为未来的重要形态。由于缺少常规交流同步发电机组和可靠备用容量,特大型新能源基地稳定性挑战、新能源利用率与供电充裕性矛盾凸显,其形态结构及演化路径成为当前关切的热点问题。系统梳理了当前最新学术研究成果,研判特大型新能源基地未来可能的源网形态并做特征分析;进一步,面向特大型新能源基地系统强度弱、灵活性不足、源网协调运行矛盾突出等挑战,针对性提出源网协调规划 ...
张玮   +5 more
core   +1 more source

基于等效电路阻尼稳定性判据的风电经柔性直流并网振荡风险与影响因素分析 [PDF]

open access: yes全球能源互联网, 2018
柔性直流输电技术在大规模风电送出中应用越来越广泛,但存在因风电和柔直各自电力电子设备控制相互作用而引发系统振荡风险。首先,为从物理意义上解释振荡机理,以阻抗分析法为基础,推导基于等效电路阻尼的互联系统稳定性判据。然后,基于此判据和时域仿真结果,分析风机网侧变流器、锁相环和柔性直流换流器的控制带宽与振荡风险的关系,指出系统振荡频率随控制参数改变的变化规律。最后,分析风速和并网风机台数对风电经柔性直流送出系统的等效电路阻尼特性影响,提出振荡稳定性约束的控制参数设计要求。
王潇   +4 more
doaj   +1 more source

考虑换流器伪量测建模的交直流混联电网状态估计方法 [PDF]

open access: yes全球能源互联网, 2022
随着直流源储荷的接入与柔性直流电力电子设备的发展,含多种分布式电源(distributed generation,DG)的交直流混联电网被认为是未来电网的主流架构,这给系统操作带来了更多灵活性,但也加剧了量测数据不足的问题,使得系统状态估计求解更加困难。目前成熟的交流状态估计未计及直流系统状态量和量测量的特征及各类DG出力的不确定性,且通常默认换流器控制方式已知,控制方法未知时的伪量测建模技术有待研究。采用计及电压源换流器(voltage source converter,VSC)损耗的模型 ...
李幸芝   +4 more
doaj   +1 more source

±500 kV柔直电网与新能源和常规发电机组的协调控制研究 [PDF]

open access: yes全球能源互联网, 2018
张北±500 kV四端柔直电网工程的送端张北站和康保站作为新能源外送的汇集站,分别连接大规模风电场群,受端北京站和丰宁站分别作为新能源消纳中心和柔直电网的功率平衡节点与华北地区交流电网相连接,丰宁站建有抽蓄机组为系统提供紧急功率支撑。整个工程结构复杂,风电场群出力间歇性、随机性大,柔直系统直流电压对多端有功功率的吞吐平衡量敏感性强,受端负荷中心对电能质量要求高,这为柔直换流器、新能源风电机组和抽蓄机组的控制提出了严峻挑战。针对三者的协调控制展开研究,为柔直送端换流器设计了带频率附加控制的V-f控制 ...
王炳辉   +6 more
doaj   +1 more source