Results 11 to 20 of about 120 (75)
Study on Maximum Power Tracking Strategy of 10 MW Medium Voltage Six-Phase Direct-Drive Permanent Magnet Wind Turbine [PDF]
In order to maximize the grid-connected power of high-power offshore wind turbines, a maximum power tracking strategy suitable for medium voltage six-phase permanent magnet synchronous generator (MVSPMSG) was proposed in the paper based on the use of ...
BAI Ru +5 more
core +1 more source
Research on Flexible Interconnection of Urban Power Grid [PDF]
[Introduction] Due to its flexibility and rapid control ability, voltage source converter based high voltage direct current (VSC-HVDC) technology can be used in asynchronous grid interconnection, renewable energy grid-connection, and urban grid power ...
Jinchuan GUO +3 more
core +1 more source
Identification of Low-Voltage Distribution Network Attribution Relationship and Phase Information Based on Density Clustering [PDF]
[Introduction] The correct topology information recorded by the power supply department can help the staff monitor the power grid information, analyze the faults, and optimize the operation of the power grid to meet the needs of lean and intelligent ...
Donghui YAN
core +1 more source
针对中国第一个海上风电柔性直流送出工程—江苏如东工程,从系统拓扑方案构建、过电压与绝缘配合、系统功率盈余问题与交流故障穿越技术以及控制保护技术等方面开展了深入研究,构建了轻型紧凑化的海上风电柔性直流系统拓扑方案,取消了海上换流站的启动回路与接地回路等;提出了海陆换流站的避雷器配置方案与参考电压的选取原则,形成了海陆换流站的绝缘配合方案的典型范式;提出了集中式、分布式、混合式直流侧有功功率动态平衡装置的典型拓扑方式,解决了陆上换流站交流侧故障穿越难题;提出了工程的整体控制保护方案 ...
卢亚军 +6 more
core +1 more source
适用于直流配电网故障选线的电力电子变压器分步闭锁方案 [PDF]
级联H桥型电力电子变压器(power electronic transformer with cascaded H-bridge,CHB-PET)是柔性变电站的重要组成设备之一,在直流配电网中具有重要作用。当CHB-PET低压直流侧发生双极短路故障后,故障电流上升速度快且幅值较高,易导致电力电子器件迅速闭锁,使低压直流电网保护难以准确获取故障信息。针对CHB-PET低压侧多分支直流配电网,提出一种基于PET分步闭锁的故障穿越策略。当检测到PET低压侧直流系统故障后 ...
于弘洋 +5 more
core +1 more source
柔性直流并入城市电网后对换流站近区短路电流的影响研究 [PDF]
大型城市供电电网短路电流已经接近断路器遮断容量,柔性直流接入系统后,会在故障期间提供工作电流,导致交流系统短路电流超标,柔性直流输送功率受限。从柔性直流内外环控制方式及交流系统短路电流计算原理出发,分析得出柔性直流短路电流的幅值和相位对并网点的短路电流影响均较大,其中幅值受外环电流限幅环节的影响易于控制,因此需着重对相位进行控制。基于此提出了一种降低柔性直流输电换流站两端PCC点短路电流的控制策略。以厦门柔性直流工程为例,开发了交直流混合模型,与实测波形对比验证了模型的正确性。通过对不同类型故障下 ...
寇龙泽, 朱琳, 范征, 谷怀广
core +1 more source
Electricity Transmission Strategy Research Based on Wind-Coal-Battery-Hydrogen-CCUS Multi Energy Coupling and Bundling System [PDF]
[Introduction] In order to guarantee urban power supply and offshore wind power utilization without building new power lines, the paper aims to establish a electricity transmission strategy based on wind-coal-battery- hydrogen -CCUS multi energy coupling
Jiamin YIN +7 more
core +1 more source
Analysis of Current Situation and Future Development of Offshore Wind Power Industry [PDF]
[Introduction] Under the trend of accelerating the clean transformation of coastal energy and adjusting the industrial structure, offshore wind power will become an important support for the safe, clean and efficient transformation of power energy in ...
Jiachang LIU +3 more
core +1 more source
混合型MMC换流器过调制下的热-电应力分布特性研究 [PDF]
全/半桥子模块混合型模块化多电平换流器(modular multilevel converter,MMC)由于具备直流故障穿越能力并兼顾了制造成本,成为当下柔性直流输电领域的研究热点之一。全桥子模块具备负电平输出能力,混合型MMC可以提升电压调制比,运行在过调制状态,提升运行效率。但是混合型MMC在过调制运行工况下的电流、热应力分布特性尚不明晰,为此针对混合型MMC在过调制下的全/半桥子模块开关器件的电流应力及热应力展开研究。通过分析混合型MMC在过调制下的工作原理和特性 ...
盛景, 董玉斐, 李武华
doaj +1 more source
目前模块化多电平换流器已经成为全球柔性直流输电工程建设的首选,并在直流配电技术领域得到了进一步的广泛应用。文中针对模块化多电平换流器在应用过程中需要面临的子模块检测工作量大、效果差、功能覆盖不全等问题,对其检测技术进行了研究。首先结合相关技术标准和实际生产需求分析了检测现状,然后基于目前两种主流检测方法的技术原理和特点提出了一种全新的模块化多电平换流器子模块检测方法,最后通过仿真验证了该方法的合理性和可行性,能够实现多个子模块的一次性自动检测,覆盖了子模块中除晶闸管外的所有功率组件 ...
杨贵军 +5 more
doaj