Results 61 to 70 of about 833,358 (231)
From Policy Neglect to Research Agenda: Administrative Burdens and Donor‐Conceived Mobilization
ABSTRACT Donor‐conceived adults are a growing population, mobilizing against the very regulatory arrangements that determined the terms into which they were conceived. In Canada and the United States, where donor conception remains persistently under‐regulated, gamete donation policy has historically prioritized the presumed needs of donors, recipient ...
Ashley Splawinski
wiley +1 more source
本发明涉及细胞内活性氧与还原型谷胱甘肽的检测,具体地说是一种同时测定细胞活性氧与还原型谷胱甘肽的检测方法,采用微流控芯片对细胞活性氧和还原型谷胱甘肽同时测定,微流控芯片电泳采用的缓冲液浓度为20- 50mM,缓冲液pH值为8.0-10.1,分离电压为200-450V/cm,检测点距进样通道和分离通道交叉处为1.0-3.0cm。本发明的检测方法样品用量非常少(3- 4uL),在微流控芯片上实现了对细胞内活性氧和还原型谷胱甘肽的同时测定,分析时间仅用27秒,且检测灵敏度较高(amol-zmol ...
林炳承 +4 more
core
The Problem With Problem Load: Reconceptualizing Load in the Multiple Streams Framework
ABSTRACT What happens when policymaking systems buckle under pressure, disrupting consensus and stalling decision‐making? Drawing on the Multiple Streams Framework, we show that the existing concept capturing this stress, Problem Load, has been both misinterpreted and overstretched.
Dana A. Dolan, Nikolaos Zahariadis
wiley +1 more source
用ICP-AES法测定水中磷,讨论并确定了试验的最佳测定条件,在选定的最佳条件下测磷的检出限为 0.02mg/L,回收率为 96.5 %~ 10 2 .1%,RSD为 1.65 %~ 2 .83 %。该法准确、快速、简便,应用于水中磷的测定,结果满意。
谢华林
doaj +2 more sources
本发明公开了一种快速微藻光谱测定仪,是一种可以快速测定微藻吸收光谱的装置。由光源,滤光片,前狭缝,检测池,后狭缝,分光镜,检测器,自动取样装置等组成。可以在微藻培养过程中,在线连续采集近红外(约900nm)至近紫外(约350nm)的微藻吸收光谱数据,也可以取样后离线采集。本装置即可作为微藻生理状态评估使用,也可与控制系统偶联 ...
褚亚东, 薛松, 曹旭鹏
core
ABSTRACT Surface‐enhanced Raman scattering (SERS) has emerged as a highly sensitive and specific technique for tumor imaging, owing to its narrow spectral features, resistance to photobleaching, and capability for multiplexed detection. However, its clinical translation remains limited by poor tissue penetration and the absence of intrinsic anatomical ...
Xinyu Miao +7 more
wiley +1 more source
铜、钴、镍、铅、锌、镉极谱分析,难点在于钴和锌的测定。在多种底液中,钴和锌半波电位相当接近,不能连续测定。文献成功地分开了钴、锌和镍波。文献利用钴波的不可逆性,逆向电压扫描测定锌。有人以萃取—反萃取方式将铜、钴、镍和铅、锌、镉分成两组实施测定。 本工作试验了用萃取—反萃取法分离,极谱测定红土矿中铜、钴、镍、铅、锌 ...
杜士奎, 于道成, 李华祥
core
ABSTRACT Wearable sweat sensors face persistent trade‐offs between multiplexed detection, signal stability, and wearing comfort. Here, we present a Janus electronic skin (e‐skin) with dual‐mode functionality, offering both thermal and moisture comfort.
Zhi‐Mei Mu +12 more
wiley +1 more source
本文从工程实际出发,以提高基于模型的单目视觉位姿测量系统的测量精度为目标,分析摄像机标定空间与测量结果误差的关系.证明了无论测量区域的成像范围多小,在满视场成像范围内设计标定空间时摄像机内参数的标定误差都最小,由此得到的位姿测量精度最高 ...
朱枫, 郝颖明, 付双飞, 周静
core
ABSTRACT Aqueous Zn‐ion batteries (AZIBs) are expected to become one of the most promising candidates for large‐scale energy storage, but are impeded by uncontrollable dendrite growth and parasitic reactions. In this study, we propose a simple mechanical shot‐peening (SP) approach for restructuring commercial Zn foils into highly exposed (002)‐textured
Xu Ma +7 more
wiley +1 more source

