Results 91 to 100 of about 3,998 (153)
Research on Fault Diagnosis Method of Photovoltaic Arrays Based on Improved Grey Wolf Algorithm Optimized Extreme Learning Machine [PDF]
ObjectivesPhotovoltaic arrays operating under complex outdoor conditions encounter various fault types with varying degrees of severity. To accurately assess the working status of photovoltaic arrays, a fault diagnosis method based on an improved grey ...
HAN Maolin +4 more
core +1 more source
笔者提出了改进型桥路模型,该模型可限制瞬态短路电流和稳态短路电流。文中对电阻型、桥式和改进桥式超导限流器进行了仿真,提出了高温超导限流器的技术方案和技术参数,在此基础上研制了10 kV高压系统的高温超导限流器。限流器于2005年8月14日在湖南省娄底电业局高溪110 kV变电站进行了短路试验,并挂网运行。短路试验中,成功将3 500 A(有效值)限制到635 A(有效值),且短路瞬间波形无突变。从6个月的运行经验来看,超导限流器各种运行指标良好,为超导限流器的规模应用奠定了基础。
陆佳政 +4 more
doaj
Research of laser and solar hybrid powered system for Active optical-electronic current transformer [PDF]
随着电力工业的不断发展,电网电压等级的不断提高,对电压、电流的测量要求也在不断提高。传统的电磁式互感器无法满足迅速发展的数字化电网电压的测试要求。目前电子式(光电式)互感器已成为电网中高电压、高电流测量新的研究热点,有源式光电电流互感器是新型互感器研究的典型代表,而高压端的供能是有源式光电电流互感器的关键部件之一。目前研究的主要有线圈从母线上取能、高压电容分压式供能、激光供能、蓄电池供能、超声电源供能等供能方法。 本文在光电互感器基本原理理论研究的基础上,对上述各种供能方法进行分析研究,结合激光供能 ...
孙存淼
core
为实现线路避雷器的带电拆换,本研究设计了一种基于磁吸力的电气连接方式,仿真计算了金属连接线在短路电流冲击和雷电流冲击下的温升和电动力,给出了连接线截面积和磁吸插头磁吸力的选择。温升仿真表明:极限条件下的短路电流会使连接线的温升急剧升高,选择截面积为25 mm2及以上的连接线能耐受短路电流的冲击,而雷电流冲击不会使连接线发生烧蚀,4/10 μs、65 kA雷电流作用下的最大温升为2.26℃,100 kA雷电流作用下的最大温升为5.35℃。电动力仿真表明:连接线受到的电动力与与短路电流的平方呈正相关 ...
李逸帆, 沈海滨, 金海, 陈康
doaj
随着中国电力工业的不断发展,大容量发电机断路器的研究也走向更高的容量等级,容量试验是发电机断路器研究、开发过程中必备的关键性环节。鉴于国家标准GB/T 14824—2008《高压交流发电机断路器》相对于当前的试验需求的不足,文中在研究即将颁布的国际标准IEC/IEEE 62271-37-013:2014(草案版)的基础上,分析与讨论了发电机断路器的短路故障、短路试验程序、以及与输配电高压交流断路器短路故障的区别,最后介绍与分析了XIHARI大容量试验站进行额定电压24 kV、额定短路开断电流160 k ...
高享想 +6 more
doaj
The Application of Residual Current Protection Device in The Electrical Fire Prevention [PDF]
剩余电流动作保护装置是防范电气火灾的有效方法之一。本文结合规范要求及系统原理对剩余电流动作保护装置在防范火灾中的应用做了几点阐述和总结。The residual current protection device is one of the effective methods to prevent electrical fires.This paper introduces some points and summarizes the application of residual current ...
张晓山
core
Research on Shadow Mitigation Strategy for Sloped Photovoltaic Arrays Based on Environmental Parameter Model [PDF]
ObjectivesThe anti-shadow strategy plays a vital role in the large-scale application of photovoltaic systems. In order to cope with the problem of power generation loss caused by shadow shading between photovoltaic arrays in areas with low slope, it is ...
HUANG Bin +5 more
core +1 more source
基于变压器磁—路—力数字模型的永久性短路故障下重合闸配置研究
为研究电力系统永久性短路故障重合闸失败造成二次冲击的系统故障问题,文中搭建重合闸短路冲击电路数字模型,计算并对比了一次短路电流和不同合闸角及剩磁作用下的二次短路电流。同时建立了变压器三维磁—路—力有限元仿真模型,获得了漏磁场及电磁力数值分布。结果表明,变压器在永久性短路故障重合闸后二次短路冲击电流会与剩磁激励产生的电流矢量叠加,三相绕组最大短路电流和所受最大电磁力在0°~180°范围内先减小后增大,在90°时达到最小值。并且同一次短路相比,合闸角为90°时轴向电磁力减小40.21%,辐向减小34.30%,
王谦 +11 more
doaj
基于高速开关(fast-opening switch,FS)和并联电容电流强制转移原理的混合型直流断路器在直流系统短路电流分断中具有广泛的应用。但是,通过单阶段转移将故障电流从FS转移至并联电容器时,由于转移过程持续时间短,电容器需要在很短的时间内吸收系统电感中存储的能量,因此高速开关触头间过电压上升速率非常高,容易引起FS发生击穿而导致开断失败。针对上述问题,文中提出了一种基于两阶段电流转移的新型直流断路器,通过转移电路的晶闸管控制故障电流分两阶段给电容器充电,不仅可以实现FS无弧打开 ...
林友福, 陈敏, 王万亭
doaj
晶闸管换流阀作为传统高压直流输电的重要设备,其可靠性和故障耐受性能与高压直流输电工程的安全可靠运行密切相关。而短路故障是晶闸管换流阀可能出现的最严重的故障之一,有必要对其进行故障分析和试验验证。文章研究了相关标准中对于短路故障的试验要求,分析了高压直流输电晶闸管换流阀的各种典型故障特性和现有的分别采用短路发电机和电容器组作为短路试验电源的两种故障电流试验方法,并从故障电流热效应等效性和故障电流试验电压等效性方面分析了两种试验方法的特点。
徐子萌 +7 more
doaj