Results 1 to 10 of about 2,348 (103)
Abstract Many species are restricted to a marginal or suboptimal fraction of their historical range due to anthropogenic impacts, making it hard to interpret their ecological preferences from modern‐day data alone. However, inferring past ecological states is limited by the availability of robust data and biases in historical archives, posing a ...
Tom B. Letessier +8 more
wiley +1 more source
为了提高高速列车运行安全稳定性,防止车顶绝缘子在雾霾天气下发生污闪,对污秽颗粒在绝缘子表面的沉积过程进行受力分析,根据受力分析结果对车顶绝缘子进行结构优化,提出两种空气动力结构绝缘子,并对优化结构进行流体力学仿真与风洞积污试验。结果表明:相比于传统结构绝缘子,空气动力结构绝缘子绕流速度大幅度提升,背风面流线有序不存在逆流现象,边界层分离点延后,旋涡运动大幅度减弱,气流分布状况得到了良好改善。空气动力型绝缘子的背风面积污量大幅减小,表面整体积污量小于传统结构绝缘子,积污更容易达到饱和,且污秽分布更加均匀。
陈然 +4 more
doaj
复合绝缘是空气绝缘开关设备小型化设计的一种重要绝缘方式。复合绝缘结构的PT(电压互感器)柜运行情况表明,该类型产品的绝缘故障率较高,特别是在湿度和污秽联合影响下,因绝缘结构设计不当的产品很容易产生局部放电,进而引发相间短路。究其原因,绝缘隔板是相间短路的"桥梁"。文中对一起24 kV PT手车三相短路事故原因进行了详细分析,通过电场仿真结果可以看出:在复合绝缘结构中,高压对绝缘板之间的距离是复合绝缘结构设计的关键。文中的故障分析以及电场分析为新产品开发与故障诊断提供了有益的参考。
王志川 +5 more
doaj
为了实现固态变压器绝缘性能的提升,满足其电压等级提升和紧凑型一体化设计的需求,利用遗传算法与电场仿真联合方法优化了固态变压器高压连接处绝缘结构。首先通过建立一体化固态变压器的绝缘结构模型,计算了稳态电场分布状态及局域电场集中位置,发现高频变压器与电力电子模块连接处接地截止点局域最高电场达6.97 kV/mm,高于空气击穿强度。其次设计了圆弧形模块连接绝缘结构将接地截止点埋入固体绝缘介质中,并通过遗传算法与电场仿真联合方法优化了圆弧形结构尺寸参数,使得连接处最高电场转移至固体绝缘介质内部 ...
袁妮, 吴俊丽, 冷兆云
doaj
结构小型化和高绝缘水平的优化设计是固封极柱设计中的重要组成部分。以40.5 kV高海拔穿墙式固封极柱为例,通过对普通结构、外绝缘加高结构、伞裙优化与屏蔽优化相结合等不同结构形式的固封极柱的电场进行分析,实现了绝缘结构的最优化。解决了40.5 kV高海拔穿墙式固封极柱的绝缘问题和局部放电问题,为类似40.5 kV穿墙式固封极柱的绝缘结构优化提供了参考。
李红梅, 王志川, 刘玉春
doaj
ABSTRACT For over 30 years, the northern Mexican state of Chihuahua bordering Texas and New Mexico has experienced and witnessed multiple forms of violence across its rural and urban regions. Communities are besieged with cartel and gender‐based violence and the saturation of international corporations that pay less than livable wages for workers in ...
Sylvia Fernández Quintanilla +1 more
wiley +1 more source
ABSTRACT This paper provides a retrospective on California's oversight of 1,3‐dichloropropene (1,3‐D). It utilizes archival documents, including internal memos, emails, and risk assessments, to demonstrate how the state's Department of Pesticide Regulation consistently expanded allowable 1,3‐D use while presenting each policy change as scientifically ...
Kaitlyn Alvarez Noli
wiley +1 more source
根据大型脉冲功率装置中的绝缘堆的结构特点,设计了一个新的四层轴向小型绝缘堆.它由四层绝缘环构成,分隔水界面与真空界面.在该绝缘结构开展静电场计算和电路仿真计算后,进行了有机玻璃小型绝缘堆的真空沿面闪络实验,实验结果反映了有机玻璃圆环结构的耐压特性.根据实验结果推算圆环结构下有机玻璃的材料常数,并计算了绝缘堆的闪络概率.圆环绝缘结构的尺寸大于一般真空沿面闪络实验中常用的圆柱与圆台结构绝缘子,结构和尺寸更接近于实际工程应用的绝缘堆结构,从实验结果中得到的关键材料常数将更适用于评估大型绝缘堆结构的闪络概率.
杨尊 +5 more
doaj
采用复合绝缘代替纯空气绝缘的金属封闭开关柜,实现了空气绝缘开关柜的小型化。但其多种绝缘介质以及绝缘界面共存的复杂结构,对电场分布以及其绝缘能力的评估带来了很大的困难。文中针对空气绝缘开关柜中的固封—手车式断路器触臂处复合绝缘结构进行了研究,通过对不同绝缘结构和绝缘材料在各电气间隙情况下的绝缘能力进行仿真和试验,结果表明:电场仿真中的最大电场强度不能作为评判复合绝缘击穿的标准,复合绝缘结构中的关键部位,如小间隙、界面等处的电场大小对绝缘耐受能力具有决定性的意义 ...
谭东现 +5 more
doaj
回顾总结了国内外的特高压变压器技术现状,介绍了特高压换流变的作用、绝缘结构特点以及换流变的绝缘试验,指出了特高压换流变压器800 kV端绝缘结构耐压水平最高达到1 257 kV以及阀侧套管和出线装置、陡波对绕组纵绝缘的影响和阀侧引出线等绝缘结构薄弱点,为特高压直流换流变的绝缘结构设计制造提供理论依据。
赵鑫 +6 more
doaj