Results 51 to 60 of about 3,961 (150)
ABSTRACT Considering the multiple challenges faced by stealth coatings in complex service environments, the development of multifunctional integrated microwave absorbing materials (MAMs) that combine efficient electromagnetic (EM) attenuation with environmental tolerance has become an urgent need. In this work, coral‐like CoNi@Void@C microparticle (MP)
Jiale Wu +8 more
wiley +1 more source
Decentralized Control of Tall Buildings Under Earthquake [PDF]
随着近年来大型结构的不断涌现,系统传统集中控制方法中所需要的传感器、控制器和作动器功能的要求也相应提高。系统越大,单个控制器破坏率越大,整个系统更容易导致瘫痪。为了克服这些问题,提出了分散控制理论。结构的分散控制是指将复杂的大型结构分为多个子结构,子结构控制器独立决策并施加控制力。分散控制方法的研究包括分散控制的结构形式、工作原理。本论文在已有研究的基础上,提出了一种新的分散控制方法,并结合最小二乘方法、半主动控制理论进行了研究,具体内容包括: 首先,本论文提出了地震激励作用下结构分散控制的新方法 ...
林英
core
ABSTRACT Bangladesh's goal of achieving high‐income status by 2041 requires dependable, low‐emission, and affordable energy. With near‐universal grid coverage and increasing demand, nuclear energy is a strategic asset for long‐term baseload supply. However, the existing financing model, typified by the country's most expensive $12.65 billion Rooppur ...
Hafiz Ahmed
wiley +1 more source
含可更换剪切型耗能梁段钢框筒利用位于裙梁跨中的耗能梁段集中塑性变形,有利于震后耗能梁段的替换和结构使用功能的快速恢复。为研究耗能梁段的构造对子结构和耗能梁段滞回性能的影响,基于某一30层原型结构的子结构,考察了耗能梁段长度、腹板高厚比、翼缘宽厚比、加劲肋间距、加劲肋单双面布置的影响。研究表明:随着耗能梁段长度的增加,子结构的承载力逐渐减小,耗能梁段的超强系数、塑性转角逐渐减小,建议耗能梁段的长度取柱距的(0.15~0.24)倍;随着腹板高厚比的增大,各子结构的承载力、累积耗能明显减小,耗能梁段的超强系数、
关彬林, 连鸣, 苏明周
doaj
利用加设钢支撑改变单跨框架结构体系的抗震加固效果研究 [PDF]
单跨框架结构大量存在于中小学建筑中,中小学建筑已提高到乙类设防,根据抗震鉴定标准GB50023-2009,框架结构不宜为单跨框架;乙类设防时,不应为单跨框架。单跨框架是一种抗震严重不利体系,缺乏冗余约束,易发生整体倒塌。若从构件加固层次提高建筑的抗震性能,不但造价高、施工复杂,而且效果也不明显。加设支撑是一种改变建筑结构体系的方法,本文结合工程实例,讨论了加设钢支撑后原结构性能变化以及加固过程中应该注意的问题。研究表明,利用支撑改变结构受力体系,可以明显改善结构性能 ...
廖文彬 +3 more
core
ABSTRACT Although magnetic carbon materials possess significant potential in the field of electromagnetic wave absorption (EWA) due to the synergistic effect of multiple attenuation mechanisms, the currently reported magnetic carbon EWA materials face some challenges, such as high cost, low yield, and easy agglomeration of the magnetic component ...
Bo Jiang +9 more
wiley +1 more source
ABSTRACT The central challenge in the development of high‐performance electromagnetic wave‐absorbing materials lies in achieving an optimal balance between impedance matching and attenuation characteristics. This is particularly critical for purely dielectric absorbers, where precise tailoring of the real (ε′) and imaginary (ε″) parts of the complex ...
Zhixiao Wang +7 more
wiley +1 more source
设防地震和罕遇地震作用下,中心支撑结构的支撑斜杆容易受压失稳。为了避免支撑斜杆失稳,提出了连接板件屈服耗能支撑。采用有限元软件ABAQUS分析了不同设计参数下连接板件屈服耗能支撑的滞回性能。分析结果表明:连接板件屈服耗能支撑利用连接板件的弯曲屈服耗能,滞回曲线饱满,耗能能力优越。连接板件最窄处的宽度、板件高度、厚度以及数量是影响支撑力学性能的重要因素。推导了支撑初始刚度及屈服承载力的理论公式,公式计算结果与有限元分析结果吻合较好,可为工程应用提供参考。
李真真, 赵宝成
doaj
Influence of Reinforced Concrete Column Ductibility by the Reinforcement Ratios and the Match of Reinforced [PDF]
影响钢筋混凝土框架柱延性的主要因素有轴压比、剪跨比、配箍特征值、纵向钢筋的配筋率及配筋形式。在我国,轴压比、剪跨比、配箍特征值对柱延性影响的研究已日趋成熟,研究成果大多被现行设计规范采纳,然而纵向钢筋的配筋率及配筋形式对柱延性影响的研究较少。本文通过非线性数值模拟,系统研究了纵向钢筋配筋率、配筋形式及核心配筋宽度对柱延性的影响,给出了相应的设计方法。 钢筋混凝土柱非线性数值模拟首先要解决的问题是约束混凝土柱的模拟,本文采用调整配箍特征值及箍筋本构模型的方法,成功模拟了约束混凝土柱的荷载-位移曲线 ...
夏再海
core
考虑阻尼器导向装置对锅炉钢结构抗震性能的影响,在SAP2000软件中采用时程分析法分别对未布置阻尼器、布置位移型阻尼器和布置黏滞型阻尼器的1 000 MW锅炉钢结构进行有限元分析,对比锅炉钢结构在地震作用下的底部剪力、顶点位移等结构响应和阻尼器耗能能力,并给出了相应的结构附加阻尼比。结果表明:在6度(0.05g)多遇地震作用下,布置黏滞型阻尼器的锅炉钢结构较布置位移型阻尼器的锅炉钢结构的底部剪力和顶点位移优化效果更佳;位移型阻尼器的耗能效果不佳,为结构附加的阻尼比较小,最大仅为0.004 5 ...
叶露 +5 more
core +1 more source

