Results 31 to 40 of about 12,505 (167)
ABSTRACT Moisture‐enabled electricity generation technology offers a new paradigm for sustainable energy harvesting, but its practical applications are still limited by issues such as low output power and insufficient long‐term stability. In this paper, an asymmetric sandwich‐structured hydrogel moist–electric generator (SSHMEG) with an ion ...
Peng Chen +7 more
wiley +1 more source
智能电表的广泛应用伴随着严重的雷电灾害威胁,需要对智能电表雷电感应过电压防护进行详细分析。利用ATP软件搭建配电系统模型,编程计算线路雷电感应过电压,分析雷击点距线路距离和回击速度对智能电表终端过电压的影响,讨论安装线路避雷器、变压器低压侧避雷器、末端SPD的防护效果。分析结果表明:10 kV线路附近发生雷击时,感应过电压传递至智能电表终端时幅值仍然较高,50 kA雷电流幅值下终端过电压超过IV类设备冲击耐受电压;智能电表终端过电压随着雷击点距线路垂直距离的增加、回击速度的减小而降低 ...
王兆军 +6 more
doaj
Design and Implementation of Power Quality Analyzing System [PDF]
随着科学技术和国民经济的快速发展,各种工业生产对电力系统电能质量的要求越来越高。然而,现代电力电子设备和非线性负载的大量使用又造成电能污染日趋严重,电能质量成为电力部门及其用户日益关注的问题。 本文首先分析了电能质量问题的产生和国内外关于电能质量分析软件的发展情况,以及有关电能质量的定义和术语的标准化问题。详细描述了我国关于电能质量的六项标准中指标的定义及相关限值:电压偏差、频率偏差、公网谐波、电压波动和闪变、三相电压不平衡及暂态过电压和瞬态过电压,并结合国标和受关注的暂态事件提出本系统使用到的指标 ...
陈明金
core
ABSTRACT The Schottky barrier height (SBH), which serves as a pivotal determinant of charge carrier injection efficiency in electronic devices, critically governs electrical behavior at metal/semiconductor interfaces. However, pronounced metal‐induced gap states at metal contact interfaces induce Fermi‐level pinning, which constrains the ...
Xiaofei Liu +10 more
wiley +1 more source
为保证126 kV单断口真空断路器挂网运行和操作过电压测试的安全,进行了断路器的操作过电压仿真计算和过电压保护研究。首先,确定断路器运行方式和建模数据;然后,EMTP建模仿真计算切合变压器和空载线路的操作过电压,并与变压器操作过电压的实际测试结果对比分析;最后,根据仿真计算提出过电压保护方案。结果表明,126 kV真空断路器的操作过电压较高,切空载变压器的过电压值低,不需要采取过电压保护措施,切负载变压器的过电压程度较高,应采取过电压保护措施,与现场测试结果一致;空载线路中由于110 ...
时振堂 +4 more
doaj
ABSTRACT High‐entropy alloys (HEAs) have attracted considerable interest from researchers owing to their tunable chemical compositions, exceptional structural stability, and promising catalytic properties. However, their large‐scale application is often hindered by complex manufacturing techniques and poor durability.
Sheng Guo +9 more
wiley +1 more source
随着电子式电能表的广泛应用,其受到的雷害威胁日益严重,迫切需要分析电能表雷电浪涌过电压以对其进行合理防护。利用EMTP软件建立简化的配电系统模型,计算电能表遭受的雷电浪涌过电压,讨论配电避雷器安装方式对电能表终端浪涌过电压的影响,研究电能表前端安装SPD的防护效果,最后分析柱上变压器距电能表不同距离和不同SPD接地电阻下电能表过电压。研究结果表明:流过电能表的电流和电能表的对地过电压波形均呈现较为明显的振荡,且波头时间较短。电能表的对地过电压幅值较高,极易超过其冲击耐受电压 ...
李霖, 曹彤, 荆臻
doaj
ABSTRACT In conventional piezoceramics, the coordinated change between the dielectric constant (εr) and the piezoelectric charge constant (d33) usually limits the piezoelectric voltage constant g33 (g33 = d33/εr), a critical figure of merit for piezoelectric sensors.
Xiaoying Feng +7 more
wiley +1 more source
为了研究换流站交流滤波器母线接入高抗后,操作该高抗产生的过电压,详细分析了切母线高抗引起的截流过电压和合闸过电压,并建立了换流站接入系统的EMTP模型,对母线高抗的操作过电压进行仿真计算。研究结果表明,随断路器截断电流值的增大,由分闸产生的操作过电压(包括截流过电压、断路器断口恢复电压和恢复电压上升率)较高;而合母线高抗未产生谐振过电压,也没有滤波器在合闸过程中过载。得出,在高抗侧并联一组避雷器能够有效地限制此过电压。
李振强 +6 more
doaj
The Design and Realization of Electric Power Quality Monitoring System Based on Virtual Instrument Technology [PDF]
在电力市场环境下,电能质量将影响电能的价格。随着我国经济的发展,各种工业生产对电能质量的要求越来越高,及时准确地得到电能质量参数,对于工业生产有重要的指导意义。不同的电力用户对电能质量有不同的需求,解决电力系统的电能质量问题,首先就需要对电能质量参数进行实时的监测和分析,从而能够正确评估电能质量的好坏,及时地找出引起电能质量恶化的原因,进一步提出解决电能质量问题的整改方案,为有关部门采取有效措施隔离或降低电能质量恶化的危害提供决策支持,因此需要对电能质量进行科学的评估 ...
陈栩
core

