Results 21 to 30 of about 3,662 (112)
Gallium‐Doped α‐MnO2 Cathode for High‐Performance Aqueous Zinc‐Ion Batteries
ABSTRACT Rechargeable aqueous zinc‐ion batteries (ZIBs) have received significant attention because of their high safety and low cost. MnO2 as a cathode material hampers the application of ZIBs due to its structural instability and dissolution during the operation of the battery.
Wen‐yu Xu +13 more
wiley +1 more source
Review of additively manufactured zinc alloys by laser powder bed fusion for biomedical applications
Graphical abstract AbstractZinc (Zn) and its alloys have emerged as promising candidates for biomedical materials, owing to their controlled degradation kinetics, intrinsic biocompatibility, and the release Zn2+ ions which are known to promote bone regeneration and tissue healing.
Xuan Yang +5 more
wiley +1 more source
高土壤电阻率地区柔性石墨复合接地材料与圆钢接地材料的有效长度对比研究
改善杆塔接地能够有效的降低输电线路雷击跳闸率,对于高土壤电阻率地区的杆塔,减小冲击接地电阻是降低雷击跳闸率的关键,而减小接地体冲击接地电阻可以通过延长接地体长度来实现,但是当长度超过一定值时,延长将不再有效。因此研究接地体的有效长度、选取有效长度更长的接地材料,对降低接地电阻有着重要意义。首先分析了接地体有效长度的物理意义,然后运用CDEGS仿真软件计算工程中常用的镀锌钢和柔性石墨复合材料水平接地体的工频接地电阻与接地体长度、冲击接地电阻与接地体长度之间的关系 ...
张昌 +5 more
doaj
随着电力网不断建设,丘陵、山区地带的杆塔数目也逐渐增多,这些地区土质贫瘠、地形复杂,易发生雷击事故,因此有必要对临坡杆塔接地网进行研究。笔者采用数值模拟的办法,应用仿真软件CDEGS,建立单边、双边和方框辅助接地网模型,接地材料选用镀锌钢、柔性石墨接地体和高导柔性石墨接地体,通过对比不同材料接地网间的分流系数和接地电阻,分析了外延引线长度、电流频率和土壤电阻率对不同材料接地网散流特性的影响。计算结果表明:随着外延引线增长、土壤电阻率增大,各材料分流系数均增大,其中高导石墨接地材料具有最好的散流特性 ...
连学森 +5 more
doaj
Graphical abstract AbstractIn this work, a conventional HfO2 gate dielectric layer is replaced with a 3‐nm ferroelectric (Fe) HZO layer in the gate stacks of advanced fin field‐effect transistors (FinFETs). Fe‐induced characteristics, e.g., negative drain induced barrier lowering (N‐DIBL) and negative differential resistance (NDR), are clearly observed
Zhao‐Hao Zhang +10 more
wiley +1 more source
隔声材料是治理噪声环境污染的重要途径之一,采用双螺杆挤出法制备聚碳酸酯/纳米二氧化硅复合材料。测试了复合材料的储能模量、损耗因子和隔声性能。结果表明:随着纳米填料二氧化硅添加量的增加,复合材料的储能模量提高,损耗因子峰值逐渐降低,复合材料的玻璃化转变温度及阻尼温域均向高温方向移动,阻尼温域变宽;5 mm聚碳酸酯基体材料的计权隔声量为24.4 dB,加入纳米二氧化硅填料后复合材料隔声性能有明显改善,在纳米二氧化硅添加量为3 phr时,复合材料隔声性能达到最大,计权隔声量达到为27.5 dB ...
王广周 +6 more
doaj
雷击是造成输电线路发生跳闸和停运事故的主要原因。"防雷在于接地",对输电线路的接地网的冲击接地特性进行研究改进对于防止雷击事故有着不可或缺作用。本文在不考虑火花放电效应和考虑火花放电效应两方面对钢、铜、石墨复合接地材料的接地网冲击接地阻抗进行对比分析。同时,采用ATP-EMTP建立了考虑火花效应时的接地散流模型,研究了土壤电阻率、接地网面积及冲击电流幅值对接地网冲击接地特性的影响。研究结果表明:考虑火花放电效应时,接地材料的冲击接地阻抗相比不考虑火花放电有所降低 ...
高晓晶 +7 more
doaj
为了制得性能稳定的碳—陶瓷线性电阻片,该研究对电阻片制造过程中的混料工艺进行了系统的研究。首先对炭黑的加入方式进行了对比,然后对炭黑与黏土材料的混料时间、料水比进行了系统研究,获得了混料时间、料水比对电阻片性能的影响规律,并最终确定了较优的混料工艺参数。实验结果表明,炭黑先球磨分散后再与黏土混合有利于降低电阻值分散性,电阻的电阻率呈现随着炭黑与粘土混料时间的增长先减小后增大的规律,电阻温度系数均随着测试温度升高先减小后增大。综合考虑,针对该配方的最佳混料工艺为分步混合法,磨球选?6锆球 ...
陈蕊 +7 more
doaj
基于复合材料塔头的110 kV双回输电线路反击耐雷性能仿真分析
复合材料杆塔以其突出的机械性能、绝缘性能和环境友好性,是未来国家电网输电线路杆塔改造的重要发展方向,开展复合材料杆塔输电各项关键技术的研究工作十分重要。针对目前提出的复合材料塔头与金属角钢塔身组合而成的"半绝缘结构复合材料杆塔",采用顺线方向垂直引下接地的防雷设计方案,考虑感应电压和工作电压的影响,通过EMTP/ATP仿真计算获得其反击一相闪络和两相闪络的耐雷水平,并分析了接地电阻对耐雷水平的影响。计算结果表明:随着接地电阻从10Ω升高到20Ω,半绝缘结构复合材料杆塔反击一相闪络的耐雷水平降低了82 ...
张廼龙 +4 more
doaj
针对当前降阻剂腐蚀性强、稳定性差等问题,利用化学氧化聚合法,合成了一种新型复合材料,即膨润土/聚吡咯(MMT/PPy),通过添加缓蚀剂等成分制备出了新型大分子降阻剂,采用控制变量法和失重法得到了降阻剂的最佳配方,采用红外光谱(FTIR)、扫描电镜(SEM)和能谱(EDS)对其进行表征分析,并对制备的新型大分子降阻剂进行性能试验研究。结果表明:MMT/PPy复合材料的最佳配方为膨润土(MMT)20%25%,十六烷基三甲基溴化铵(CTMAB)5%8%,对甲苯磺酸钠(TASNa)12%14%,吡咯(Py)5 ...
田野, 朱志平, 周艺, 柳森
doaj