Results 1 to 10 of about 989 (118)
Discharge characteristics and discharge simulation model of long air gaps containing a floating conductor [PDF]
Long air gaps containing a floating conductor are common insulation types in power grids. During the transmission line live-line work, the process of lineman entering the transmission line air gap constitutes a live-line work combined air gap, which is a
Gao, Jiachen <1995>
core +1 more source
Research on Flexible HVDC Transmission Technology and Strategies for Improving the Operational Stability of IGBT Components [PDF]
[Introduction] With the continuous improvement of the strategic position of clean energy, more and more new energy power generation equipment is connected to the power grid, but its power quality is unstable, which has a great impact on the AC ...
Tao WANG +3 more
core +1 more source
针对中国第一个海上风电柔性直流送出工程—江苏如东工程,从系统拓扑方案构建、过电压与绝缘配合、系统功率盈余问题与交流故障穿越技术以及控制保护技术等方面开展了深入研究,构建了轻型紧凑化的海上风电柔性直流系统拓扑方案,取消了海上换流站的启动回路与接地回路等;提出了海陆换流站的避雷器配置方案与参考电压的选取原则,形成了海陆换流站的绝缘配合方案的典型范式;提出了集中式、分布式、混合式直流侧有功功率动态平衡装置的典型拓扑方式,解决了陆上换流站交流侧故障穿越难题;提出了工程的整体控制保护方案 ...
卢亚军 +6 more
core +1 more source
Research on lightning transient distribution characteristics of cable-stayed bridges [PDF]
Bridges are usually located at the junction of land and water, where the surrounding area is open terrain, making them to be easily damaged by lightning strikes.
Dajun XU +4 more
core +1 more source
GIS母线残余电压和合闸的操作冲击电压共同作用可能会造成GIS母线发生闪络,开展GIS母线有直流电压情况下叠加冲击电压试验,是研究提高GIS母线绝缘水平的必要方法。文中通过搭建直流叠加冲击电压试验回路,研制1 100 kV串联550 kV GIS母线试验平台,开展直流叠加雷电或操作冲击电压试验,结果表明:单独±2 400 kV雷电冲击电压或单独±1 800 kV操作冲击电压作用时,母线均未发生闪络;负极性直流叠加负极性冲击电压作用时,550 kV GIS母线段多次发生闪络,负 ...
操松元 +5 more
doaj
为了明晰导致10 kV配电避雷器4/10μs大电流冲击耐受失效的原因,验证大电流冲击耐受试验试品等价性,提升入网避雷器质量。笔者以10 kV配电系统用瓷外套、复合外套避雷器为研究对象,采用试验手段研究不同结构的整支避雷器及其核心元件电阻片、介电特性比例单元的大电流冲击耐受能力;对比不同结构的配电避雷器以及同一避雷器的不同试品类型之间大电流冲击耐受能力的差异,分析影响10 kV配电避雷器大电流冲击耐受能力的因素,从而为避雷器大电流冲击试验样品的选择,为电网用户选择性能优良的避雷器提供技术支撑。
王陆璐 +4 more
doaj
雷电主要是通过雷击电磁脉冲、直击雷等对自动气象站进行破坏,虽然多数气象站已经安装了接闪杆,在一定程度上保护了建筑物和人身安全,但是基于各种因素的影响,使得自动气象站防雷工作仍然存在诸多问题,基于此,本文概述了自动气象站,阐述了自动气象站中的雷电侵入途径,对自动气象站防雷工作存在的主要问题及其措施进行了探讨分析。
华林 孙, 丽萍 高
semanticscholar +1 more source
Research on Lightning Electromagnetic Coupling Suppression and Polarization State Stability of OPGW Cable based on Anti Resonant-Hollow Core Fiber [PDF]
【Objective】In the integration scenario of power and optical communication networks, the lightning electromagnetic interference faced by Optical Fiber Composite Overhead Ground Wire (OPGW) has become a key technical bottleneck restricting the system ...
BAI Yunlong +11 more
core +1 more source
避雷器在运行过程中会承受多次雷电冲击影响,其过电压防护效果值得关注。选取现场已运行19年的110 kV氧化锌阀片为研究对象,在135℃条件下进行加速交流老化试验,测试了阀片热功耗曲线及其它特征参量,并基于热加速因子的阿伦纽斯模型计算了阀片剩余寿命。进一步,以特制存在不同阀片劣化程度的避雷器为研究对象,开展了多次连续的雷电冲击电流(8/20μs, 10 kA)试验,测试了多次雷电冲击电流前后能表征避雷器电气性能的特征参量以及冲击电流、电压波形。研究发现:已服役19年的阀片剩余寿命分散性明显 ...
姜雄伟, 王文浩, 韩睿
doaj
对整只避雷器多波形冲击电流试验设备参数和整只避雷器电气参数进行计算,分析了整只避雷器冲击电流试验设备回路参数的选择对回路设计的影响,提出了一种多功能冲击电流试验设备的设计思路,按此思路研制出了一种整只避雷器试验用多波形冲击电流试验设备,该试验设备可以按标准要求进行35 kV及以下电压等级避雷器的4/10冲击电流耐受试验、8/20冲击电流波形下重复转移电荷试验以及残压试验、(200~230)μs波形下重复转移电荷试验、30/80操作冲击电流残压试验。
孙泉, 余龙龙, 刘云蔚, 田泽群
doaj