Results 1 to 10 of about 2,822,267 (158)

27-Gauge Vitrectomy for Symptomatic Vitreous Floaters with Topical Anesthesia [PDF]

open access: yesCase Reports in Ophthalmology, 2017
Purpose: Traditionally acceptable methods of anesthesia for vitrectomy surgery are quite varied. However, each of these methods has its own potential for complications that can range from minor to severe.
Zhong Lin   +3 more
doaj   +3 more sources

Influences of 27-Gauge Vitrectomy on Corneal Topographic Conditions [PDF]

open access: yesJournal of Ophthalmology, 2017
Purpose. To evaluate the influences of 27-gauge vitrectomy on corneal topographic conditions. Method. Fifty-six eyes of 56 patients undergoing 27-gauge vitrectomy were retrospectively studied.
Takafumi Hirashima   +3 more
doaj   +3 more sources

Comparative study of straight vs angled incision in 27-gauge vitrectomy for epiretinal membrane [PDF]

open access: yesClinical Ophthalmology, 2018
Ryo Yomoda, Hiroki Sasaki, Jiro Kogo, Akira Shiono, Tatsuya Jujo, Reio Sekine, Naoto Tokuda, Yasushi Kitaoka, Hitoshi Takagi Department of Ophthalmology, St Marianna University School of Medicine, Kawasaki, Kanagawa, Japan Purpose: The purpose of this ...
Yomoda R   +8 more
doaj   +3 more sources

Outcomes of Primary 27-Gauge Vitrectomy for 73 Consecutive Cases With Uveitis-Associated Vitreoretinal Disorders [PDF]

open access: yesFrontiers in Medicine, 2021
Background: Since the advent of 27-gauge microincision vitrectomy system a decade ago, evidence regarding the feasibility, safety, and effectiveness of 27-gauge pars plana vitrectomy (PPV) has increased.Aim: To assess the effectiveness and safety profile
Kyung Woo Kim   +6 more
doaj   +2 more sources

Outcomes of transconjunctival sutureless 27-gauge vitrectomy for vitreoretinal diseases [PDF]

open access: yesInternational Journal of Ophthalmology, 2018
AIM: To evaluate the safety and efficacy profile of 27-gauge (27G) pars plana vitrectomy (PPV) for the treatment of various vitreoretinal diseases. METHODS: The clinical outcomes of 61 eyes (58 patients) with various vitreoretinal diseases following 27G
Jie Li   +6 more
doaj   +2 more sources

Intraoperative Optical Coherence Tomography-Assisted 27-Gauge Vitrectomy in Eyes with Vitreoretinal Diseases [PDF]

open access: yesCase Reports in Ophthalmology, 2015
Objective: To report intraoperative optical coherence tomography (iOCT)-assisted 27-gauge microincision vitrectomy surgery (MIVS) in eyes with vitreoretinal disease.
Hiroshi Kunikata, Toru Nakazawa
doaj   +2 more sources

A comparison between topical and retrobulbar anesthesia in 27-gauge vitrectomy for vitreous floaters: a randomized controlled trial [PDF]

open access: yesBMC Ophthalmology, 2018
Background To compare the safety and efficacy of topical anesthesia versus retrobulbar anesthesia in 27-gauge pars plana vitrectomy (PPV) for vitreous floaters.
Rong Han Wu   +4 more
doaj   +2 more sources

Efficacy of 27-Gauge Vitrectomy with Internal Limiting Membrane Peeling for Epiretinal Membrane in Glaucoma Patients [PDF]

open access: yesJournal of Ophthalmology, 2019
Purpose. To evaluate the efficacy of epiretinal membrane (ERM) surgery for patients with ERM and glaucoma. Methods. We reviewed the medical records of 20 consecutive ERM patients with glaucoma, who underwent 27-gauge microincision vitrectomy surgery ...
Masaaki Yoshida   +3 more
doaj   +2 more sources

A 27-Gauge Light Pipe-Assisted Modified Kebab Technique for Safe Retrieval of a Dropped Lens Nucleus: A Case Report [PDF]

open access: yesCase Reports in Ophthalmology
Introduction: Management of dropped lens nuclei can be challenging, and several approaches have been reported, including perfluorocarbon liquid (PFCL) flotation and the kebab technique with intraocular diathermy.
Sho Yokoyama
doaj   +2 more sources

Comparison of 27-Gauge 20,000 vs. 10,000 cuts per minute vitrectomy systems in epiretinal membrane surgery: a randomized clinical trial [PDF]

open access: yesScientific Reports
Recent advances in 27-gauge vitrectomy technology have led to the development of 20,000 cuts-per-minute (CPM; 20 K) systems aimed at enhancing surgical efficiency.
Yong Je Choi   +5 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy