Results 201 to 210 of about 8,871,631 (366)

A Python package for fast GPU‐based proton pencil beam dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya   +4 more
wiley   +1 more source

Implementation of needle‐tracking technology for real‐time transrectal ultrasound‐guided interstitial gynecological HDR brachytherapy: A feasibility study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To investigate the feasibility of adapting a commercial prostate biopsy system for transrectal ultrasound (TRUS)‐guided hybrid gynecological (GYN) high‐dose‐rate (HDR) brachytherapy (BT). Leveraging 3D‐TRUS and MR image fusion, the prototype system aims to improve real‐time needle placement accuracy.
Lindsey H. Bloom   +8 more
wiley   +1 more source

The 300 H.P. Benz Aircraft Engine [PDF]

open access: yes
A description is given of the Benz 12-cylinder aircraft engine. The 300 H.P. engine, with the cylinders placed at an angle of 60 degrees not only realizes a long-cherished conception, but has received refinement in detail.
Heller, A
core   +1 more source

Correction: Analysis of Predefined Safety Events Across Spesolimab Trials in Dermatological and Non-Dermatological Conditions. [PDF]

open access: yesDermatol Ther (Heidelb)
Gordon KB   +11 more
europepmc   +1 more source

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Automated rapidplan model validation using Eclipse scripting API

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy