Results 141 to 150 of about 1,627,552 (307)

Aberration correction in 3D transthoracic echocardiography

open access: yesWFUMB Ultrasound Open
Three-dimensional cardiac imaging has been available in the clinic for more than two decades. Continuous improvement in image quality has occurred in this period due to the development of probe technology and beamforming techniques.
Svein-Erik Måsøy   +9 more
doaj   +1 more source

Highlights of right ventricular characteristics of left ventricular noncompaction using 3D echocardiography. [PDF]

open access: yesInt J Cardiol Heart Vasc, 2023
Horváth M   +10 more
europepmc   +1 more source

Myocardial abscess secondary to staphylococcal septicemia: Diagnosis with 3D echocardiography

open access: yes, 2013
A 56 years old gentleman with staphylococcal septicemia with metastatic abscesses in spleen and heart. Real time 3D trans thoracic echocardiography could not only confirm the diagnosis of myocardial abscess but also well delineate it and identify ...
Pankaj Jariwala   +4 more
core   +1 more source

Learning Curve of Pentaspline Pulsed‐Field Ablation With Posterior Wall Isolation for Persistent Atrial Fibrillation

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Background Pentaspline pulsed‐field ablation (PFA) has emerged as a novel modality for pulmonary vein isolation (PVI) and posterior wall isolation (PWI) in persistent atrial fibrillation (AF). However, the learning curve associated with combined PVI + PWI and the contribution of anatomical factors to acute lesion completeness remain ...
Atsuhiko Yagishita   +5 more
wiley   +1 more source

Navigating the Zero Fluoroscopy Frontier: Current Tools, Evidence and Future Directions in Electrophysiology Procedures

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Graphical Abstract ABSTRACT Fluoroscopy has traditionally been the mainstay imaging technique for guidance during electrophysiology (EP) ablation procedures. The numerous disadvantages associated with radiation exposure for both operators and patients have created the need for zero‐fluoroscopy (ZF) approaches. Today, electrophysiologists have access to
Dimitrios Kotzadamis   +6 more
wiley   +1 more source

Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study. [PDF]

open access: yesJ Cardiovasc Imaging, 2023
Mani A   +4 more
europepmc   +1 more source

Cryoballoon Versus Radiofrequency Ablation for Persistent Atrial Fibrillation: Meta‐Analysis of Randomized Trials

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Introduction Pulmonary vein isolation (PVI) alone achieves modest arrhythmia freedom in persistent atrial fibrillation (PeAF). Cryoballoon ablation (CBA) offers a single‐shot alternative to radiofrequency ablation (RFA) that streamlines procedural workflow.
Harroop Bola   +8 more
wiley   +1 more source

Tailoring the Atrioventricular Interval During Left Bundle Branch Pacing: Playing With Fusion

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Optimization of biventricular pacing for cardiac resynchronization therapy (CRT) with fusion (fusion‐optimized intervals method) has been shown to improve left ventricular remodeling. However, information on programming the atrioventricular (AV) interval during left bundle branch pacing (LBBP) is scarce.
Margarida Pujol‐Lopez   +9 more
wiley   +1 more source

Share - Publish - Store - Preserve. Methodologies, Tools and Challenges for 3D Use in Social Sciences and Humanities

open access: yes, 2020
"Through this White Paper, which gathers contributions from experts of 3D data as well as professionals concerned with the interoperability and sustainability of 3D research data, the PARTHENOS project aims at highlighting some of the current issues they
Consortium 3D SHS Team
core  

Home - About - Disclaimer - Privacy