Results 21 to 30 of about 1,627,552 (307)

Real-Time 3D Fusion Echocardiography

open access: yesJACC: Cardiovascular Imaging, 2010
This study assessed 3-dimensional fusion echocardiography (3DFE), combining several real-time 3-dimensional echocardiography (RT3DE) full volumes from different transducer positions, for improvement in quality and completeness of the reconstructed image.The RT3DE technique has limited image quality and completeness of datasets even with current matrix ...
Szmigielski, C   +7 more
openaire   +4 more sources

What Does 3D Echocardiography Add to 2D Echocardiography in the Assessment of Mitral Regurgitation? [PDF]

open access: yes, 2017
Purpose of Review: The purpose of this review was to elucidate the additional value of 3D echocardiography for the assessment of mitral regurgitation (MR) compared to standard 2D echocardiography.
Contu L.   +6 more
core   +2 more sources

Assessment of Mitral Regurgitation Severity by measuring of Vena Contracta Area Using Transesophageal and Transthoracic Three-Dimensional Echocardiography [PDF]

open access: yesAl-Azhar International Medical Journal, 2020
Background: Mitral regurgitation (MR) is one of the most common derangement of native valves and increases in prevalence with age. We aimed to compare the accuracy of the vena contracta area measurement (VCA) by 3-dimensional transesophageal (3D-TEE ...
Ahmed Algarhi, Ali Al Amin
doaj   +1 more source

3D Echocardiography: Is CMR better? [PDF]

open access: yesEuropean Journal of Echocardiography, 2006
The question, as put in this way, cannot be answered in a simple manner since the answer depends on many variables, i.e. type of patient, pathology, circumstances, clinical question, etc. In the setting of a regular operating theater or an intensive care unit, CMR is totally irrelevant since the patient cannot be moved to the MR machine; if the patient
openaire   +2 more sources

3D echocardiography: The present and the future [PDF]

open access: yesJournal of Cardiology, 2008
3D echocardiography has been proven to be useful for clarifying complicated cardiac anatomies and hemodynamics. Recently introduced real-time 3D TEE may overcome technical and quality problems and result in widespread use of 3D echocardiography in routine clinical settings.
openaire   +2 more sources

Correlation Between Acute Impairment of Regional Contractility and Left Ventricular Remodeling after Revascularized Acute Myocardial Infarction

open access: yesJournal of Cardiovascular Emergencies, 2015
Introduction: The present study aims to demonstrate the role of acute impairment of regional contractility, as assessed by 3D echocardiography, in predicting LV remodeling in post acute myocardial infarction (AMI) patients.
Nyulas Tiberiu   +6 more
doaj   +1 more source

Head to head comparison of 2D vs real time 3D dipyridamole stress echocardiography

open access: yesCardiovascular Ultrasound, 2008
Real-time three-dimensional (RT-3D) echocardiography has entered the clinical practice but true incremental value over standard two-dimensional echocardiography (2D) remains uncertain when applied to stress echo.
Basso Massimiliano   +5 more
doaj   +1 more source

On the characterization of athlete’s heart using 3D echocardiography

open access: yesEuropean Journal of Preventive Cardiology, 2022
This editorial refers to ‘Biventricular mechanical pattern of the athlete’s heart: comprehensive characterization using 3D echocardiography’, by A. Fábián et al., https:// doi.org/10.1093/eurjpc/zwac026.
Andre La Gerche   +4 more
openaire   +5 more sources

3D Harmonic Echocardiography: [PDF]

open access: yes, 2007
Three dimensional (3D) echocardiography has recently developed from an experimental technique in the ’90 towards an imaging modality for the daily clinical practice. This dissertation describes the considerations, implementation, validation and
Voormolen, M.M. (Marco)
core   +1 more source

An example of 3D speckle-tracking echocardiography (3D-STE) myocardial deformation analysis performed using TomTec 4D LV-Analysis.

open access: yes, 2023
An example of 3D speckle-tracking echocardiography (3D-STE) myocardial deformation analysis performed using TomTec 4D LV-Analysis.
Jamil Mayet (395080)   +6 more
core   +1 more source

Home - About - Disclaimer - Privacy