Results 31 to 40 of about 1,186 (154)

Investigation of 54Fe(n,γ)55Fe and 35Cl(n, γ)36Cl reaction cross sections at keV energies by Accelerator Mass Spectrometry [PDF]

open access: yesEPJ Web of Conferences, 2020
Activations with neutrons in the keV energy range were routinely performed at the Karlsruhe Institute of Technology (KIT) in Germany in order to simulate stellar conditions for neutron-capture cross sections. A quasi-Maxwell-Boltzmann neutron spectrum of
Slavkovská Zuzana   +12 more
doaj   +1 more source

Detachable three-layer Au absorber microfabrication for low-temperature detectors

open access: yesMicro and Nano Engineering, 2023
Low temperature detectors (LTDs) used for decay energy spectrometry (DES) can provide accurate and reliable decay data thanks to their high-energy resolution and a near 100% detection efficiency for the radiations of interest. However, it is essential to
Jawad Hadid   +7 more
doaj   +1 more source

The Determination of M Shell Average Fluorescence Parameters From 70Yb to 92U and of Hg, Pb and Bi Compounds Using 5.96 keV Photons

open access: yesCumhuriyet Science Journal, 2018
In this study, the empirical average Mshell fluorescence yields were calculated from 70Yb to 92U.These obtained values will supply more experimental data for theoreticalestimations of atomic structure calculations and spectroscopic analysis whichis used ...
Engin Tıraşoğlu   +3 more
doaj   +1 more source

Gamma-ray shielding parameters analysis for some polymers using Phy-X/PSD and WinXCom [PDF]

open access: yesE3S Web of Conferences
In this paper, the characteristics of gamma-ray attenuation of various polymers like PTFE, PMMA, POM and PA-6 were measured using the Phy-X/PSD program and the XCOM program for different sources of gamma radiation like 22Na, 55Fe, 60Co, 109Cd, 131I ...
Al‑Hasnawy Ruaa. S., Kadhim Rashid O.
doaj   +1 more source

Effect of Scintillation Cocktail and Quenching Calibration Method on Measurement of 55Fe by LSC

open access: yesHe huaxue yu fangshe huaxue
In order to optimize the measurement conditions of 55Fe by liquid scintillation counting, the effect of three kinds of commercial scintillation cocktail and two efficiency correction methods on LSC measurements of 55Fe was tested.
MA Li-na   +4 more
doaj   +1 more source

Nuclide separation technology and engineering application of radioactive oil for NPPs

open access: yesHe jishu, 2023
BackgroundRadioactive oil is one of the organic "difficult wastes" produced by the operation of nuclear power plants.PurposeThis study aims to develop a nuclide separation and treatment technology for radioactive waste oil and explore engineering ...
FENG Wendong   +8 more
doaj   +1 more source

Gas electron multiplier (GEM) foil test, repair and effective gain calculation

open access: yesResults in Physics, 2018
The focus of my research is based on the gas electron multiplier (GEM) foil test, repairing and effective gain calculation of GEM detector. During my research work define procedure of GEM foil testing short-circuit, detection short-circuits in the foil ...
Muhammad Tahir   +4 more
doaj   +1 more source

A novel ceramic GEM used for neutron detection

open access: yesNuclear Engineering and Technology, 2020
A novel ceramic Gas Electron Multiplier (GEM) has been developed to meet the demand of high counting rate for the neutron detection which is an alternative to 3He-based detector at China Spallation Neutron Source (CSNS).
Jianrong Zhou   +15 more
doaj   +1 more source

Development of μ-PIC with resistive electrodes using sputtered carbon

open access: yesEPJ Web of Conferences, 2018
The Micro Pixel Chamber (μ-PIC) has been developed for a hadron-collider experiment. The main purpose is detecting Minimum Ionizing Particles (MIP) under high-rate Highly Ionizing Particles (HIP) environment.
Yamane Fumiya   +8 more
doaj   +1 more source

Characterization of Monolithic Active Pixel Sensors for future collider experiments [PDF]

open access: yesEPJ Web of Conferences
In high-energy physics experiments, Monolithic Active Pixel Sensors (MAPS) have become crucial components of vertex and tracking detectors over the past decade due to the integration of readout circuitry with the detection volume in a single chip.
Colelli Angelo   +8 more
doaj   +1 more source