Ablation evaluations of structural constraint mechanism on KITTI.
Ablation evaluations of structural constraint mechanism on KITTI.
Shaofan Wang (12562797) +3 more
core +1 more source
Advances in Imaging for Atrial Fibrillation Ablation [PDF]
Over the last fifteen years, our understanding of the pathophysiology of atrial fibrillation (AF) has paved the way for ablation to be utilized as an effective treatment option.
Andrew D'Silva +3 more
core +1 more source
PURPOSE: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, occurring in 1-2% of the general population. Catheter ablation has become an important treatment modality for patients with symptomatic drug-refractory AF.
Guida P. +8 more
core +1 more source
Mechanisms of ablation-rate decrease in multiple-pulse laser ablation
We present two sets of experimental results on the ablation-rate decrease with increase of the number of consecutive laser pulses hitting the same spot on the target surface. We have studied laser ablation of a carbon target with nanosecond pulses in two different interaction regimes: one with a XeCl laser (λ=308 nm) and the other with a Nd:YAG laser ...
E. G. Gamaly +3 more
openaire +2 more sources
Ablation resistance properties and microstructure of plasma spraying coatings
Tungsten (W) and tungsten alloy coatings were prepared by plasma spraying on 45# steel and TC4 titanium alloys. Ablation tests were carried out under the different ablation conditions.
LIN Bingtao +5 more
doaj +1 more source
Background Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and is associated with a deterioration of clinical status. Ablation of symptomatic AF is an established therapy, but in HCM, the characteristics of recurrent
Leon Dinshaw +13 more
doaj +1 more source
Effect of Particle Concentration on Ablation Behavior of Carbon/Carbon Composites
A self-designed oxygen-kerosene ablation system was employed to study the ablation mechanism and performance of the carbon-carbon composites. Particle concentrations of the gas-solid two-phase ablation flow were 0, 1.37%, 2.22%, and 2.64% respectively ...
ZHA Bai-lin +6 more
doaj +1 more source
Which patients recur as atrial tachycardia rather than atrial fibrillation after catheter ablation of atrial fibrillation? [PDF]
The ablation gaps have been known as the main mechanism of recurrence as atrial tachycardia (AT) rather than atrial fibrillation (AF) after AF catheter ablation.
Pil-Sung Yang +6 more
doaj +1 more source
Catheter ablation of atrial fibrillation: Past, present, and future directions
Atrial fibrillation (AF) is the most common cardiac arrhythmia encountered in clinical practice. Because of inadequate efficacy of pharmacological therapy, catheter ablation of AF has evolved dramatically over the last decade.
Kentaro Yoshida, Kazutaka Aonuma
doaj +1 more source
Characterization of the aerosol produced by infrared femtosecond laser ablation of polyacrylamide gels for the sensitive inductively coupled plasma mass spectrometry detection of selenoproteins [PDF]
A 2D high repetition rate femtosecondlaserablation strategy (2-mm wide lane) previously developed for the detection of selenoproteins in gel electrophoresis by inductively coupled plasma mass spectrometry was found to increase signal sensitivity by a ...
Claverie, Fanny +20 more