Results 91 to 100 of about 15,962 (230)

Waste heat recovery via organic rankine cycle: results of a era-SME technology transfer project [PDF]

open access: yes, 2013
The main goal of the EraSME project “Waste heat recovery via an Organic Rankine Cycle”, completed by partners Howest (Belgium), Ghent University (Belgium) and University of Applied Sciences Stuttgart (Germany) between 1 January 2010 and 31 December 2012,
De Paepe, Michel   +4 more
core  

Messdaten zur Absorptionskälteanlage FA2 [PDF]

open access: yes, 2018
This contribution provides measured data of a single stage H2O/LiBr absorption chiller under partload conditions.Berliner Senatsverwaltung für Stadtentwicklung im Rahmen des Umweltentlastungsprogramms (UEP), 10530, Solare Klimatisierung von ...
Kühn, Annett
core   +1 more source

Increasing electrical power output and fuel efficiency of gas engines in integrated energy system by absorption chiller scavenge air cooling on the base of monitoring data treatment

open access: yesE3S Web of Conferences, 2018
An advanced scavenge air cooling system for reciprocating gas engines of integrated energy system for combined electricity, heat and refrigeration generation has been developed.
Radchenko Andrii   +3 more
doaj   +1 more source

Solar absorption chiller performance prediction based on the selection of principal component analysis

open access: yesCase Studies in Thermal Engineering, 2019
In this paper, a method to predict the performance of an absorption chiller using solar thermal collectors as the energy input is analyzed rigorously. Artificial Neural Network (ANN) is developed based on experimental data to predict the performance of ...
Nasruddin   +5 more
doaj   +1 more source

SOLAR POWERING OF HIGH EFFICIENCY ABSORPTION CHILLER

open access: yes, 2004
This is the Final Report for two solar cooling projects under this Cooperative Agreement. The first solar cooling project is a roof-integrated solar cooling and heating system, called the Power Roof{trademark}, which began operation in Raleigh, North Carolina in late July 2002.
openaire   +3 more sources

Performance analysis of a new single effect hot water absorption chiller system [PDF]

open access: yes, 2015
University of Technology Sydney. Faculty of Engineering and Information Technology.Conventional air conditioning significantly contributes to primary electricity consumption.
Sinha, S
core  

METHOD OF DETERMINATION OF THERMAL LOAD AIR CONDITIONING SYSTEMS BY MAXIMUM COLD PERFORMANCE RATE (on the example of air conditioning for energy purposes)

open access: yesАвіаційно-космічна техніка та технологія, 2018
It is justified the necessity of taking into consideration changes in thermal loads on the air conditioning system (heat and moisture treatment of air by cooling it with decreasing temperature and moisture content) in accordance with the current climatic
Микола Іванович Радченко   +4 more
doaj   +1 more source

Performance evaluation of the Solar Building Test Facility [PDF]

open access: yes
The general performance of the NASA Solar Building Test Facility (SBTF) and its subsystems and components over a four year operational period is discussed, and data are provided for a typical one year period.
Jensen, R. N.
core   +1 more source

Solar cooling: a case study [PDF]

open access: yes, 2011
Throughout the years various methods for heat prevention and indoor temperatures control in the summer have been used. The alternative cooling strategies are based on various passive and low energy cooling technologies for protection of the buildings ...
A. CEFALO   +2 more
core  

Performance of Steam Absorption Rate and Refrigeration Efficiency of LiBr Aqueous Solution added with Active Carbon Particles

open access: yesZhileng xuebao, 2012
To enhance the steam absorption rate and refrigeration efficiency of a absorption chiller, the active carbon/LiBr suspension was made up of a little active carbon particles and LiBr aqueous solution based on higher absorption performance of active carbon.
Cai Jie   +2 more
doaj  

Home - About - Disclaimer - Privacy