Results 21 to 30 of about 423 (182)

Scheduling of Multiple Chillers in Trigeneration Plants

open access: yesEnergies, 2015
The scheduling of both absorption cycle and vapour compression cycle chillers in trigeneration plants is investigated in this work. Many trigeneration plants use absorption cycle chillers only but there are potential performance advantages to be gained ...
Chris Underwood, Bobo Ng, Francis Yik
doaj   +1 more source

Techno-economic relevance of absorption chillers to enhance existing 3GDH

open access: yesEnergy Reports, 2021
This article studies the economical, technical and environmental aspects of a third generation district heating (DH) network with absorption chillers installed at substation level in order to satisfy the cooling demands. This network solution hence takes
B. Nérot   +4 more
doaj   +1 more source

Absorption Chillers: Technology for the Future

open access: yesEnergy Engineering, 1997
ABSTRACT In an era of heightened awareness of energy efficiency and the associated environmental impacts, many industries worldwide are exploring “environmentally friendly” technologies that provide equivalent or improved performance while reducing or eliminating harmful side-effects. The refrigeration and air-conditioning industry, due to its reliance
Patricia Welesko Garland   +1 more
openaire   +1 more source

Study on Relative COP Changes with Increasing Heat Input Temperatures of Double Effect Steam Absorption Chillers

open access: yesMATEC Web of Conferences, 2016
Absorption chillers at cogeneration plants generate chilled water using steam supplied by heat recovery steam generators. The chillers are mainly of double effect type.
Abd Majid Mohd Amin, Nordin Adzuieen
doaj   +1 more source

Variable flow and optimization of chiller loading effect on energy saving for screw vapor compression-single effect absorption hybrid chiller plant in hospital mechanical room ‒ case study: Tehran heart hospital

open access: yesMechanics & Industry, 2021
Chiller plants are the most energy consuming system during summer season in residential, commercial and hospital buildings. The highly variable cooling demand of the buildings connected to a hybrid chiller plant included absorption and vapor compression ...
Boghosian Ronald   +3 more
doaj   +1 more source

Studies on Steam Absorption Chillers Performance at a Cogeneration Plant

open access: yesMATEC Web of Conferences, 2014
Absorption chillers at cogeneration plants generate chilled water using steam supplied by heat recovery steam generators. The chillers can be of either single-effect or double effect configuration and the coefficient of performance (COP) depends on the ...
Abd Majid Mohd Amin   +3 more
doaj   +1 more source

Optimal Cooling Load Sharing Strategies for Different Types of Absorption Chillers in Trigeneration Plants

open access: yesEnergies, 2016
Trigeneration plants can use different types of chillers in the same plant, typically single effect and double effect absorption chillers, vapour compression chillers and also cooling storage systems.
Benedetto Conte   +2 more
doaj   +1 more source

Absorption Refrigeration Systems Based on Ammonia as Refrigerant Using Different Absorbents: Review and Applications

open access: yesEnergies, 2020
The interest in employing absorption refrigeration systems is usually related to electricity’s precariousness since these systems generally use thermal rejects for their activation.
Alvaro A. S. Lima   +6 more
doaj   +1 more source

A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application

open access: yesZhileng xuebao, 2007
LiBr-water absorption chillers are commonly adopted in multifunction energy systems. The empirical part-load performance model for chillers presented by DOE-2 is one of the analytical methods to solve chiller performances.
杨承, 杨泽亮, 蔡睿贤
doaj   +2 more sources

Compact Ammonia/Water Absorption Chiller of Different Cycle Configurations: Parametric Analysis Based on Heat Transfer Performance

open access: yesEnergies, 2022
Ammonia/water absorption chillers are driven by low-grade heat and cover wide refrigeration temperatures. This paper analyses single-stage ammonia/water absorption chillers. A numerical model was developed based on the heat exchanger performance.
Xuan Tao   +2 more
doaj   +1 more source