Results 1 to 10 of about 62,934 (293)

Mechanical Behavior and Failure Analysis of Prosthetic Retaining Screws after Long‐term Use In Vivo. Part 1: Characterization of Adhesive Wear and Structure of Retaining Screws [PDF]

open access: yes, 2007
Purpose: The general aim of this study and those presented in Parts 2–4 of this series was to characterize the structure, properties, wear, and fracture of prosthetic retaining screws in fixed detachable hybrid prostheses after long‐term use in vivo ...
Al Jabbari, Youssef S.   +4 more
core   +1 more source

Yeniden simantasyonun CAD/CAM zirkonya kuronların kısa titanyum ve zirkonya abutmentler üzerine tutunmasına etkisi

open access: yesActa Odontologica Turcica, 2020
Amaç: Bu çalışmanın amacı yeniden simantasyon işleminin bir self adeziv rezin siman ile kısa titanyum ve zirkonya dayanaklara yapıştırılan zirkonya kopinglerin tutuculuğuna etkilerinin karşılaştırmalı olarak değerlendirilmesidir.
Nurullah Türker   +1 more
doaj   +1 more source

Effect of time yield in concrete upon deformation stresses in a reinforced concrete arch bridge : a report [PDF]

open access: yes, 1935
Cover title.Prepared as part of an investigation conducted by the Engineering Experiment Station, University of Illinois at Urbana ...
Kluge, Ralph Wendel, 1905-   +1 more
core  

Apparatus for sequentially transporting containers [PDF]

open access: yes, 1982
Apparatus for transferring and manipulating a plurality of containers in a sequence is disclosed including a mechanical manipulator arm having a gripping device which automatically picks up a container at a fixed pickup position P and transfers it to a ...
Hudgins, J. L.
core   +1 more source

Effect of laser-dimpled titanium surfaces on attachment of epithelial-like cells and fibroblasts. [PDF]

open access: yes, 2015
PurposeThe objective of this study was to conduct an in vitro comparative evaluation of polished and laserdimpled titanium (Ti) surfaces to determine whether either surface has an advantage in promoting the attachment of epithelial-like cells and ...
Ansari, Sahar   +6 more
core   +2 more sources

Effects of Blood Contamination and Decontamination Protocol on Reverse Torque Value of Abutment Screws in Dental Implants: An In Vitro Study [PDF]

open access: gold, 2023
Hafiz Adawi   +8 more
openalex   +1 more source

Fire extinguishing apparatus having a slidable mass for a penetrator nozzle [PDF]

open access: yes, 1980
A fire extinguishing apparatus for delivering an extinguishing agent through a tarrier surrounding a structure into its interior includes an elongated tubular nozzle body which has a pointed penetrating head carried on one end of the tubular body.
Bolton, P. N.   +2 more
core   +1 more source

The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported Restorations

open access: yesSelcuk Dental Journal
Background: The purpose of this study was to analyze the effect of vent hole or peripheral groove on retention of differently angled (15 ° and 30 o) abutments in of cement retained implant supported restorations.
Nuran Yanıkoğlu, Hilal Asutay
doaj   +1 more source

Three dimensional mathematical model of tooth for finite element analysis [PDF]

open access: yesSrpski Arhiv za Celokupno Lekarstvo, 2010
Introduction. The mathematical model of the abutment tooth is the starting point of the finite element analysis of stress and deformation of dental structures. The simplest and easiest way is to form a model according to the literature data of dimensions
Puškar Tatjana   +6 more
doaj   +1 more source

RIOT: a simple graphical assembly tool [PDF]

open access: yes, 1982
Errors in the chip assembly process are harder to find than errors in cell design, since they belong to no specific part of the design, but rather to the assembly as a whole. Assembly errors are more costly than call design errors also, since they often
Rowson, Jim, Trimberger, Stephen
core  

Home - About - Disclaimer - Privacy