Microleakage and Torque Loss at the Implant-Abutment Interface in Original Versus Non-Original Abutments: An In Vitro Study. [PDF]
Sánchez-Benito F +4 more
europepmc +1 more source
Suitability of Endoscopic Full Thickness Resection for Appendiceal Orifice Polyps
ANZ Journal of Surgery, EarlyView.
Sophie Brown +2 more
wiley +1 more source
ABSTRACT Objectives This study evaluated the accuracy, time efficiency, and workflow consistency of artificial intelligence (AI)‐assisted versus human expert (HI) implant planning in the esthetic anterior maxilla. Material and Methods Thirty‐five single‐tooth anterior maxillary cases with paired cone beam computed tomography (CBCT) and intraoral scans (
Eslam Abdelwahab Dawood +3 more
wiley +1 more source
Differential effects of abutment contamination within an internal hexagonal connection on preload formation and load-dependent preload loss. [PDF]
Sun M, Shin J, Park Y, Shim JS, Kim J.
europepmc +1 more source
ABSTRACT Objectives This RCT evaluated and compared the clinical performance of zirconia and titanium dental implants placed in the maxillary premolar region. Outcomes were assessed 3 years after prosthetic loading and included marginal bone level (MBL) changes, clinical parameters, aesthetic outcomes, and patient related outcome measures (PROMs ...
J. H. W. de Beus +8 more
wiley +1 more source
Evaluation of micro-gap at implant abutment interface using different connection design. [PDF]
D V +6 more
europepmc +1 more source
ABSTRACT Objectives To evaluate the fracture resistance, fracture modes, and crystalline phase changes of zirconia one‐piece implants (OPI) and bone‐level (BLTPI) or tissue‐level, two‐piece implants (TLTPI), with ceramic (C) or titanium (T) abutment screws after dynamic preloading in a moist environment.
Abdulaziz Gul +5 more
wiley +1 more source
Effect of Access Channel Sealing and Superstructure Material on Abutment-Implant Screw Stability After Cyclic Loading: A Comparative In Vitro Study. [PDF]
Irkeç Z, Şentürk A, Orhan K.
europepmc +1 more source
ABSTRACT To assess the 5‐year dimensional stability of buccal hard‐tissues following guided bone regeneration (GBR) of peri‐implant dehiscence defects using deproteinized bovine bone mineral (DBBM) blocks or particulate. Methods Patients requiring single‐tooth implants and presenting a buccal dehiscence defect (≥ 3 mm) at implant placement were ...
Anina N. Zuercher +5 more
wiley +1 more source
Management of Soft Tissue Deficiency Around an Anterior Implant Placed During the Adolescent Period: A Case Report of 30 Months Follow-Up. [PDF]
Yaman D +5 more
europepmc +1 more source