Retention of graphene-reinforced polymethyl methacrylate crowns bonded to titanium-base abutments: an exploratory in vitro study. [PDF]
Prats Sisquella B +4 more
europepmc +1 more source
ABSTRACT Objective To compare ⌀3.3 mm and ⌀4.1 mm hydrophilic titanium‐zirconium implants supporting fixed dental prostheses (FDPs) in mandibular distal‐extension situations among participants with varying degrees of hyperglycaemia. Materials and Methods Participants were stratified according to HbA1c (5.8%–< 7.0% vs.
Supriya Ebenezer +4 more
wiley +1 more source
ABSTRACT Objective To compare the 3‐year clinical, radiographic, esthetic, and patient‐reported outcomes of zirconia (Zr) and titanium (Ti) implants placed in posterior sites in a randomized, controlled within‐subject design. Materials and Methods Forty‐two patients each received one Zr and one Ti implant.
Anina N. Zuercher +5 more
wiley +1 more source
Prosthesis Survival, Complications, and Maintenance of Telescopic-Crown-Retained Removable Dental Prostheses and Root-Cap-Retained Overdentures: A Retrospective Cohort Study. [PDF]
Timoschenko A +6 more
europepmc +1 more source
Risk Factors for Implant Failure and Peri‐Implantitis: A Retrospective Cohort Study
ABSTRACT Objectives This retrospective cohort study evaluated patient‐, implant‐, site‐, procedural‐, biological‐, and prosthesis/mechanics‐related factors associated with early and late implant failure and peri‐implantitis. Material and Methods Electronic health record data from a university center were analyzed.
Nathalia Vilela +4 more
wiley +1 more source
Passive Fit in Digital Full-Arch Implant Rehabilitation: A Clinical Application of an Adaptive Titanium Base. [PDF]
Heimke J, Kurtzman GM, Blood WS.
europepmc +1 more source
Peritoneal Cystic Lymphangioma Mimicking a Femoral Hernia
ANZ Journal of Surgery, EarlyView.
Imen Ben Ismail +4 more
wiley +1 more source
ABSTRACT Objectives To evaluate the cleaning efficacy, quantitative and qualitative surface modifications of titanium (Ti) and zirconia (Zr) abutments following instrumentation with twelve mechanical instrumentation modalities. Materials and Methods Twenty‐four Ti and twenty‐four Zr abutments were divided by marginal grooves into 36 test and 12 control
Marina Salah Kamel +3 more
wiley +1 more source
Comparing fracture resistance of CAD/CAM polyetherketoneketone ″PEKK″, carbon reinforced polyetheretherketone ″CR PEEK″ and nano-zirconia implant abutments receiving digitally milled nano-zirconia and glass ceramic crowns: an in vitro study. [PDF]
Elkholy MA +3 more
europepmc +1 more source
ABSTRACT Objectives This study aimed to assess the mid‐term clinical performance of short implants as strategic support for mandibular removable partial dentures (RPDs) with free‐end situations. Methods Subjects wearing lower RPDs in Kennedy Class I situations received two supporting posterior implants.
Manrique Fonseca +6 more
wiley +1 more source