Results 71 to 80 of about 113,758 (309)
Suppression of Second-Order Harmonic Current for Droop-Controlled Distributed Energy Resource Converters in DC Microgrids [PDF]
Droop-controlled distributed energy resource converters in dc microgrids usually show low output impedances. When coupled with ac systems, second-order harmonics typically appear on the dc-bus voltage, causing significant harmonic currents at the ...
Caldognetto, Tommaso +3 more
core +1 more source
Metasurface‐engineered NC‐TENG arrays integrate tactile pressure mapping, non‐contact gesture sensing, and acoustic signal readouts in one ultrathin module, and outperforms pristine PDMS in terms of electrical output and real‐time spatial mapping for next‐gen wearables.
Injamamul Arief +12 more
wiley +1 more source
DSP Based Control Implementation of an AC/DC Converter with Improved Input Current Distortion
This paper presents a digital signal processor based control of an AC/DC converter with nearly unity power factor. Normally, the output voltage of a single-phase AC/DC converter comprises a voltage ripple with twice line-frequency.
WISUTMETHEEKORN, P., CHUNKAG, V.
doaj +1 more source
Two-stage power conversion architecture for an LED driver circuit [PDF]
This paper presents a merged-two-stage circuit topology suitable for efficient LED drivers operating from either wide-range dc input voltage or ac line voltage.
Lim, Seungbum +3 more
core +1 more source
Ga‐on‐In substitution coupled with Zn vacancies in Zn3In2S6 creates a dopantdefect synergy that weakens InO bonding and induces electronhole asymmetry. The resulting spatial charge separation directs the two‐electron oxygen reduction pathway, enabling efficient artificial photosynthesis of H2O2 with a production rate of 187.8 µmol g−1 min−1 ...
Xiaowen Ruan +10 more
wiley +1 more source
Control of hybrid AC/DC microgrid under islanding operational conditions
This paper presents control methods for hybrid AC/DC microgrid under islanding operation condition. The control schemes for AC sub-microgrid and DC sub-mi-crogrid are investigated according to the power sharing requirement and operational reliability. In
Guangqian Ding +4 more
doaj +1 more source
Konverter Ac-dc Tiga Fasa Terkendali Terhadap Total Harmonic Distortion (Thd) Pada Beban Induktif Berbasis Lab-view [PDF]
Application of non linear loads are widely used in household industries, office buildings and factories such as power converters for motor speed control of ac/dc, un-interruptible power supplies (ups) lampfluorescent using electronic ballas.
Kusnadi, K. (Kusnadi) +1 more
core
A Comprehensive Review of Waste‐Derived Materials for Solar Still Performance Enhancement
ABSTRACT Solar desalination reduces energy use and produces freshwater sustainably, but its productivity is limited and cannot meet rising demand. Thus, solar desalination system improvements are sought to boost water productivity. Waste materials are abundantly available and burden the environment, making them low‐cost enhancers for solar desalination
A. S. Abdullah +6 more
wiley +1 more source
Application of a Novel AC-DC-AC Converter in Double-fed Adjustable Speed System
By researching on principle of double-fed adjustable speed system based on traditional thyristor AC-DC-AC converter, a novel AC-DC-AC converter topology is proposed.
ZHANG Xingqi +2 more
doaj
This research aims to develop interactive multimedia-based learning media that can improve student understanding of the material DC-DC converters and AC-AC converter.
Ulfa Isni Kurnia +2 more