Results 101 to 110 of about 3,205,387 (153)

Electrical and Dielectric properties of 3, 3', 3'', 3'''-tetra poly (1, 4-diaminobenzen phthalate) phthalocyanine copper (II) thin films prepared by casting method.

open access: yesمجلة علوم ذي قار, 2019
In this study, 3, 3', 3'', 3'''-tetra poly (1, 4-diaminobenzen phthalate) phthalocyanine copper (II) film was prepared by casting method. The study consists of two parts: the first includes the measurement of electrical conductivity and activation ...
Ziyad Falak
doaj  

Electric Vehicle HV-DC EMC Filter Loss due to Variations in AC-Load Configuration

open access: yes
The motor of an electric vehicle is connected to the inverter either by cables or busbars if the inverter and motor are integrated in the same housing. Instead of a motor, an equivalent lumped load may be used during EMC pre-compliance testing. Utilizing
Rasek, Guido A.   +4 more
core   +1 more source

Erratum to : AC Losses in Superconductors

open access: yesTEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan), 1969
openaire   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

AC loss characteristics of coated conductor and the perspective for its AC loss reduction

Physica C: Superconductivity and its Applications, 2005
The AC loss characteristics of a coated conductor are determined by the combination of its electromagnetic properties, its geometrical structure, the external magnetic field to which it is exposed, and its transport current. Magnetic fields in a solenoid coil and a one-layer cable are shown as examples of the external magnetic field to which a coated ...
N. Amemiya   +5 more
openaire   +1 more source

AC losses in superconducting solenoids

IEEE Transactions on Magnetics, 1978
Losses were measured in a variety of different solenoids made from various types of superconductors. Both single filament and multifilament, twisted and untwisted, conductors were used. The results were compared with calculated losses for these cases.
W. Carr, B. Clawson, W. Vogen
openaire   +1 more source

ac losses of V3Ga tapes

Cryogenics, 1975
Abstract 60 Hz losses, measured at 4.2 K, are reported for a number of V3Ga tapes reacted between 625°C and 775°C for various lengths of time. The losses are shown to depend mainly on the bulk critical current density Jc, except at low fields (≲ 500 Oe) where surface currents, and hence surface roughness, play a dominant role.
O. Horigami, J.F. Bussiere, Y. Tanaka
openaire   +1 more source

ac Losses in Superconductors

Journal of Applied Physics, 1968
Since the discovery of technologically interesting high-field superconductors in 1961 more than 50 experimental and theoretical publications have appeared which are concerned with the relevant ac loss mechanisms. These papers are reviewed, and certain of the experimental findings are unified in the light of the present day understanding.
openaire   +1 more source

AC losses in superconducting solenoids

IEEE Transactions on Appiled Superconductivity, 2002
This paper presents an analytical model to determine AC losses in monolayer and multilayer superconducting solenoids. The case of a transformer with several coils is also presented. This model is based on an infinite cylindrical geometry and the Bean model.
E. Vinot   +3 more
openaire   +1 more source

Losses in AC Superconducting Coils

1989
AC superconducting wires are being developed so as to be applied to electrical machineries. The main concerns in developing the AC superconducting wires are AC losses. In order to assess AC losses in the form of winding, we made two AC superconducting coils having different rated capacities, 500kVA and 20kVA.
H. Kasahara   +3 more
openaire   +1 more source

AC losses of transposed superconductors

IEEE Transactions on Magnetics, 1975
Eastham and Rhodes published results of loss measurements on transposed superconducting NbTi cables and concluded basing on an extrapolation to very large numbers of wires that transposed superconductors could be used favourably in cables for power transmission. There are some reasons to question the correctness of their extrapolation.
D. Eckert, G. Enderlein, F. Lange
openaire   +1 more source

Home - About - Disclaimer - Privacy