Results 31 to 40 of about 280,821 (244)

Study on AC Resistance of Layering Enamelled Stranded Conductor

open access: yesMATEC Web of Conferences, 2019
In recent years, with the rapid development of large-length ultra-high-pressure voltage extrusion insulated submarine cable technology, the cable system in the medium-length offshore power grid interconnection project has been gradually replaced by XLPE ...
Jiang Zhenxing, Yang Liming, Zhu Zhien
doaj   +1 more source

Robust Resistive Switching Constancy and Quantum Conductance in High-k Dielectric-Based Memristor for Neuromorphic Engineering

open access: yesNanoscale Research Letters, 2022
For neuromorphic computing and high-density data storage memory, memristive devices have recently gained a lot of interest. So far, memristive devices have suffered from switching parameter instability, such as distortions in resistance values of low ...
Muhammad Ismail   +3 more
doaj   +1 more source

Influence of PWM on the proximity loss in permanent magnet brushless AC machines [PDF]

open access: yes, 2008
The winding copper loss can be significantly increased due to skin and proximity eddy current effects. The skin and proximity losses due to fundamental frequency current has been investigated in literature, but the influence of PWM on the skin and ...
Bremner, J.   +5 more
core   +1 more source

Tackling Challenges in Seebeck Coefficient Measurement of Ultra-High Resistance Samples with an AC Technique [PDF]

open access: yes, 2019
Seebeck coefficient is a widely studied semiconductor property. Conventional Seebeck coefficient measurements are based on DC voltage measurement. Normally this is performed on samples with moderate resistances (e.g., below a few MΩ level).
Pan, Z   +5 more
core   +2 more sources

DC and AC Characteristics of GaAs/InGaAs/AIGaAS Real Space Transfer Transistors

open access: yesActive and Passive Electronic Components, 1998
DC and AC performances of a GaAs/InGaAs/AIGaAs negative resistance field-effect transistor (NERFET) are demonstrated by molecular beam epitaxy (MBE) for the first time.
H. C. Chen
doaj   +1 more source

Research on the Measurement of AC Resistance of Overhead Transmission Lines Considering Actual Operating Conditions

open access: yesEnergies
The presence of alternating current (AC) resistance in overhead conductors contributes to additional energy losses during electrical energy transmission and affects the current-carrying capacity of the lines.
Dexin Xie   +6 more
doaj   +1 more source

Precise measurement of absolute Seebeck coefficient from Thomson effect using ac-dc technique

open access: yesAIP Advances, 2019
The Seebeck coefficient is the most widely measured property specific to thermoelectric materials. The absolute Seebeck coefficient S determined from the Thomson effect is highly sensitive to systematic errors incurred in the determination of the ...
Y. Amagai   +5 more
doaj   +1 more source

Fieldlike and antidamping spin-orbit torques in as-grown and annealed Ta/CoFeB/MgO layers [PDF]

open access: yes, 2014
We present a comprehensive study of the current-induced spin-orbit torques in perpendicularly magnetized Ta/CoFeB/MgO layers. The samples were annealed in steps up to 300 degrees C and characterized using x-ray absorption spectroscopy, transmission ...
Auffret, Stéphane   +16 more
core   +4 more sources

Response Surface Modeling of the Steady-State Impedance Responses of Gas Sensor Arrays Comprising Functionalized Carbon Nanotubes to Detect Ozone and Nitrogen Dioxide

open access: yesSensors, 2023
Carbon nanotube (CNT) sensors provide a versatile chemical platform for ambient monitoring of ozone (O3) and nitrogen dioxide (NO2), two important airborne pollutants known to cause acute respiratory and cardiovascular health problems.
Krishna Naishadham   +3 more
doaj   +1 more source

Dc and ac behaviour of a normal joint in a superconducting cable [PDF]

open access: yes, 1984
The application of joints which can be disassembled is studied within the framework of the development of high current (25 kA), high power (0.5 kW) cryogenic current supplies (flux pumps).1,2 The behaviour of a scale model with currents up to 5 kA will ...
Kate, H.H.J. ten   +3 more
core   +2 more sources

Home - About - Disclaimer - Privacy