Results 151 to 160 of about 1,029,186 (289)

Fast, automated optimization of virtual monoenergetic images with the dual‐energy image synthesizer for cone‐beam CT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Dual‐energy cone‐beam CT (DE‐CBCT) has become subject of recent interest due to the ability to produce virtual monoenergetic images (VMIs) with improved soft‐tissue contrast and reduced nonuniformity artifacts. However, efficient production and optimization of VMIs remains an under‐explored part of DE‐CBCT's application.
Andrew Keeler   +4 more
wiley   +1 more source

Surface dose analysis and dosimetric comparison of Halcyon versus Truebeam in breast cancer radiotherapy: An OSL dosimetry study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Breast cancer is a neoplastic disease with high prevalence among women. Radiotherapy is one of the principal treatment modalities for this disease, but it poses significant challenges. This study aimed to compare and evaluate the technical and dosimetric performance of conventional C‐arm linac systems and a new design, Halcyon, in the ...
Mustafa Çağlar   +8 more
wiley   +1 more source

Assessment of a medical physics educational program for science teachers

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Medical physics is a fulfilling profession where physics is applied to advance human health. However, many are uninformed of the role of physicists in medicine, and students are unaware of this career pathway. This study presents a pilot 1‐year program for science teachers to learn about physics in medicine and share with students
Ashley J. Cetnar   +2 more
wiley   +1 more source

Open‐source deep‐learning models for segmentation of normal structures for prostatic and gynecological high‐dose‐rate brachytherapy: Comparison of architectures

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The use of deep learning‐based auto‐contouring algorithms in various treatment planning services is increasingly common. There is a notable deficit of commercially or publicly available models trained on large or diverse datasets containing high‐dose‐rate (HDR) brachytherapy treatment scans, leading to poor performance on images ...
Andrew J. Krupien   +8 more
wiley   +1 more source

Leveraging prior mean models for faster Bayesian optimization of particle accelerators. [PDF]

open access: yesSci Rep
Boltz T   +9 more
europepmc   +1 more source

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

Implementation and validation of the method for the energy spectra reconstruction of electron beams generated by the AQURE mobile accelerator. [PDF]

open access: yesRep Pract Oncol Radiother
Ryczkowski A   +6 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy