Results 171 to 180 of about 13,744,820 (237)

Configuration‐Encoded Cell Alignment by Light‐Gated Silicon Photovoltaic Microcell Arrays

open access: yesAdvanced Functional Materials, EarlyView.
Light‐gated silicon photovoltaic microcells convert pulsed illumination into localized electrical cues. Arranging otherwise similar microcells into four‐lobed, six‐lobed, or circular patterns directs fibroblasts into corresponding local arrangements without wired stimulation.
Yifan Tao   +7 more
wiley   +1 more source

Critical Coupling in Semi‐Trasparent Fano Resonators for Photothermal Converters

open access: yesAdvanced Functional Materials, EarlyView.
An ultrathin metal–insulator multilayer architecture is engineered to exploit Fano‐resonant critical coupling, completely suppressing optical reflectance while achieving a balanced 50:50 trade‐off between absorbance and transmittance. Upon laser excitation at resonance, the metamaterial generates intense localized heat (ΔT≈550∘C$\Delta T {\approx }550^\
Giuseppe Emanuele Lio   +3 more
wiley   +1 more source

Deformation‐Tolerant Functional Elastomer Overlayers for Haze‐Assisted Light Extraction and Color Conversion in Stretchable Mechanoluminescent Films

open access: yesAdvanced Functional Materials, EarlyView.
Functional elastomer overlayers are integrated onto stretchable ZnS:Cu‐PDMS mechanoluminescent films to regulate light after emission without modifying the emissive composite. NLC‐PU provides haze‐assisted light extraction to enhance green mechanoluminescence, while DCM‐NLC‐PU combines green‐to‐yellow‐orange color conversion with enhanced outward light
Gyudam Jeon   +3 more
wiley   +1 more source

Programming Neuromorphic Plasticity Through Ionic and Electronic Coupling in Organic Electrochemical Transistors

open access: yesAdvanced Functional Materials, EarlyView.
Neuromorphic plasticity in OECTs is governed by the post‐stimulus evolution of coupled ionic and electronic states. Semiconductor chemistry and morphology, electrolyte composition and interfaces, and device architecture regulate ion injection, transport, confinement, and release, shifting responses from rapidly relaxing STP to metastable memory and ...
Inho Lee   +9 more
wiley   +1 more source

Molecular Bridges for 2D Nanomaterials

open access: yesAdvanced Functional Materials, EarlyView.
Molecular cross‐linking provides a versatile strategy to engineer interfaces in 2D materials. By tuning the linker backbone, binding mode, and interflake spacing, molecular bridges can regulate charge transport, mechanical integrity, chemical functionality, and processing.
Yudhajit Bhattacharjee   +3 more
wiley   +1 more source

Scalable Fabrication of Thermally Reconfigurable Ge Metasurfaces Using Stencil Lithography for Mid‐Infrared Molecular Fingerprinting

open access: yesAdvanced Functional Materials, EarlyView.
Scalable stencil lithography enables resist‐free fabrication of high‐index Ge metasurfaces for mid‐infrared molecular fingerprinting. Reversible thermo‐optic tuning provides post‐fabrication spectral control for precise resonance–vibration mode alignment, enabling enhanced molecular fingerprinting of microplastic particles.
Shovasis Kumar Biswas   +6 more
wiley   +1 more source

Single‐Cell Resolution Mapping of Osteoarthritis‐Associated Chondrocyte Dynamics Using a High‐Density CMOS MEA Platform

open access: yesAdvanced Healthcare Materials, EarlyView.
Single‐cell and spatially resolved impedance mapping using a high‐density CMOS‐MEA platform enables non‐invasive monitoring of osteoarthritis‐associated chondrocyte dynamics. Continuous label‐free measurements reveal heterogeneous remodeling behaviors, including proliferation, migration, and phenotypic transitions, establishing a powerful approach for ...
Neha Deshpande   +9 more
wiley   +1 more source

NeuroVisio SyncPatch: A Skin‐Conformal Multimodal EMG–Motion Sensing Platform for Quantitative Neuromuscular Rehabilitation and Performance Monitoring

open access: yesAdvanced Healthcare Materials, EarlyView.
NeuroVisio SyncPatch integrates skin‐conformal electromyography (EMG) electrodes with camera‐tracked markers to jointly assess muscle activity and three‐dimensional knee kinematics during rehabilitation. Parallel feedback pathways provide real‐time kinematic guidance during movement and post‐trial neuromuscular feedback.
Bohyung Choi   +11 more
wiley   +1 more source

Rational Control of Antibody Orientation for Enhancing Sensitivity and Specificity in Lateral Flow Immunoassays With Clinical Validation

open access: yesAdvanced Healthcare Materials, EarlyView.
Systematic investigation of antibody orientation strategies in lateral flow immunoassays reveals that a para‐substituted (aminomethyl)phenylboronic acid mediated probe (P‐6) combined with a biotin‐streptavidin test‐line modification achieves a synergistic 14‐ to 19‐fold sensitivity gain over conventional conjugation. Furthermore, multiplexed detection,
Pin‐Hao Wang   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy