Results 131 to 140 of about 121,813 (264)

Semi‐automated hippocampal avoidance whole‐brain radiotherapy planning

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Hippocampal avoidance whole‐brain radiotherapy (HA‐WBRT) is designed to spare cognitive function by reducing radiation dose to the hippocampus during the treatment of brain metastases. Current manual planning methods can be time‐consuming and may vary in quality, necessitating the development of automated approaches to streamline ...
Dong Joo Rhee   +9 more
wiley   +1 more source

Evolution of Dental Resin Adhesives-A Comprehensive Review. [PDF]

open access: yesJ Funct Biomater
Alomran WK, Nizami MZI, Xu HHK, Sun J.
europepmc   +1 more source

Professionalism skills education in medical physics residency: Current state and perceived importance

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The purpose of this study was to collect data on current practices for teaching and assessing professionalism in CAMPEP‐accredited residency programs. Methods A survey of 21 questions was sent to 160 program directors (PDs) of CAMPEP‐accredited residency programs.
Anna Rodrigues   +5 more
wiley   +1 more source

Using deep learning generated CBCT contours for online dose assessment of prostate SABR treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Prostate Stereotactic Ablative Body Radiotherapy (SABR) is an ultra‐hypofractionated treatment where small setup errors can lead to higher doses to organs at risk (OARs). Although bowel and bladder preparation protocols reduce inter‐fraction variability, inconsistent patient adherence still results in OAR variability.
Conor Sinclair Smith   +8 more
wiley   +1 more source

Effective 10-MDP Bonding to Saliva-Contaminated Dentin. [PDF]

open access: yesJ Adhes Dent
Etiennot L   +5 more
europepmc   +1 more source

Improving dose delivery in non‐coplanar cranial SRS: Stereoscopic x‐ray‐guided mitigation of table walkout errors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Purpose Linear accelerator (LINAC)‐based single‐isocenter multi‐target (SIMT) treatment has streamlined the cranial stereotactic radiosurgery (SRS) workflow. Though efficient, SIMT delivery adds additional challenges that should be considered, including increased sensitivity to rotational errors for off‐isocenter targets.
Yohan A. Walter   +4 more
wiley   +1 more source

Evaluating feature extraction reproducibility across image biomarker standardization initiative‐compliant radiomics platforms using a digital phantom

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy