Voltammetric and impedance studies of phenols and Its derivatives at carbon nanotubes/Prussian bluefilms platinum modified electrode [PDF]
The electrochemical oxidation of phenol (Ph), 4-chlorophenol (4-ClPh) and 4-nitrophenol (4-NPh) at a platinum electrode modified with and without multi-walled carbon nanotubes/Prussian blue nanocomposite in a pH 7.0 phosphate buffer electrolyte was ...
Adekunle, Abolanle S. +4 more
core
Investigation factors that control trace metal toxicity in coastal systems : a temporal and spatial analysis of kinetically inert copper in Boston Harbor [PDF]
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2004.Includes bibliographical references (p. 56-58).(cont.) form of inert Cu.
Fitzmaurice, Arthur G., 1980-
core
Usporedna procjena oksidacije amalgama kronopotenciometrijom i voltametrijom [PDF]
The characteristic features of scanned deposition potential curves constructed from stripping chronopotentiometry (SSCP) and various modes of stripping voltammetry (SSV) are critically evaluated.
Herman P. van Leeuwen, Raewyn M. Town
core +1 more source
The determination of molybdenum in selected mushrooms by stripping voltammetry
Piech Robert +3 more
doaj +1 more source
Voltammetric sensor based on Co3O4/SnO2 nanopowders for determination of diltiazem in tablets and biological fluids [PDF]
Abdol Mohammad Attaran +3 more
core +1 more source
Related searches:
Catalytic Systems in Adsorptive Stripping Voltammetry
Electroanalysis, 2000Catalytic adsorptive stripping voltammetry (CAdSV) combining adsorptive preconcentration of the electroactive species with the catalytic reaction provides a significant enhancement of the voltammetric response, and consequently a considerable decrease of the detection limit, as well as the improvement of the selectivity of the determination.
Andrzej Bobrowski, Jerzy Zarębski
openaire +3 more sources
Adsorptive Stripping Voltammetry of Bleomycin
The Analyst, 1997In 0.05 M H2SO4 solution, two reductive peaks, P1 and P2, of bleomycin were obtained. The peak potentials E(P1) and E(P2) were -0.83 and -1.09 V (versus Ag/AgCl), respectively. The sensitivity of P2 was much higher than that of P1. The peak current of P2 was proportional to the concentration of bleomycin over the range 1.0 x 10(-9)-1.0 x 10(-7) M with ...
X, Tan, J, Hu, Q, Li
openaire +2 more sources
Cathodic stripping voltammetry and adsorptive stripping voltammetry of selenium(IV)
Analytica Chimica Acta, 1988Abstract Cathodic stripping voltammetry of selenium(IV) in 0.1 M hydrochloric acid media yielded a nonlinear calibration graph for the concentration range 10−9−10−8 M. In this concentration range, adsorptive stripping voltammetry based on adsorption of the selenium/3,3′-diaminobenzidine complex on the surface of the hanging mercury drop electrode at ...
Věra Stará, Miloslav Kopanica
openaire +1 more source
Adsorptive Stripping Voltammetry of Phytohemagglutinin
Analytical Letters, 1988Abstract The adsorptive stripping voltammetric behaviour of the lectin, phytohemagglutinin, has been optimised with respect to accumulation time, accumulation potential, pulse amplitude, scan rate and drop size. Adsorptive stripping voltammetry has also been used to study the interaction of this protein with nannose, galactose and N-acetyl-D ...
Juana Rodriguez Flores +2 more
openaire +1 more source