Ahmed glaucoma valve implant: surgical technique and complications
Ivano Riva,1 Gloria Roberti,1 Francesco Oddone,1 Anastasios GP Konstas,2 Luciano Quaranta3 1IRCCS “Fondazione GB Bietti per l’Oftalmologia”, Rome, Italy; 21st University Department of Ophthalmology, Glaucoma Unit, AHEPA Hospital ...
Ivano Riva +2 more
exaly +10 more sources
Ahmed Glaucoma Valve in Aniridia [PDF]
Ahmed A Ahmed,1– 3 Peter A Netland3,4 1Department of Ophthalmology, Case Western Reserve University School of Medicine, Cleveland, OH, USA; 2Department of Ophthalmology, Assiut University, Assiut, Egypt; 3Department of Ophthalmology, University of ...
Ahmed AA, Netland PA
doaj +5 more sources
Ahmed Glaucoma Valve Implantation to Reduce Intraocular Pressure: Updated Perspectives
Gul Arikan, Uzeyir Gunenc Dokuz Eylul University School of Medicine, Department of Ophthalmology, Izmir, TurkeyCorrespondence: Gul Arikan, Dokuz Eylül University, School of Medicine, Department of Ophthalmology, Izmir, 35340, Turkey, Tel +90 531 7919687,
Gul Arikan, Uzeyir Günenç
exaly +4 more sources
Ahmed Glaucoma Valve Implantation in Jordan: Indications and Complications [PDF]
Asem A Alqudah, Ahmed G Obaidi, Mohammad Al Zoubi, Abdelwahab Aleshawi Division of Ophthalmology, Department of Special Surgery, Jordan University of Science and Technology, Irbid, 22110, JordanCorrespondence: Asem A Alqudah, Ophthalmology Service ...
Alqudah AA +3 more
doaj +4 more sources
Partial vitreous occlusion of Ahmed glaucoma valve implant with controlled intraocular pressure: a case report [PDF]
Background The Ahmed glaucoma valve implant is effective in reducing intraocular pressure, yet it poses a risk of complications such as vitreous occlusion of the tube, potentially resulting in elevated intraocular pressure or retinal issues.
Yun Jeong Lee
doaj +3 more sources
Ahmed glaucoma valve implant appears to be a relatively useful drainage device in eyes with glaucoma secondary to Sturge-Weber syndrome (SWS). However, early postoperative choroidal and exudative retinal detachment may occur from a rapid expansion of the
Sarker, Bipul Kumer De +10 more
doaj +2 more sources
Ahmed glaucoma valve implant for refractory glaucoma in children: A systematic review and meta-analysis [PDF]
Purpose The aim of this study was to evaluate the efficacy and safety of the Ahmed glaucoma valve in pediatric patients with refractory glaucoma. Methods A comprehensive literature search was conducted across multiple major databases, including PubMed ...
Xiangjun Fu +8 more
doaj +2 more sources
Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma
Amir Pirouzian1, Joseph L Demer21Department of Ophthalmology, San Diego Children’s Hospital, San Diego, UCSD, San Diego, CA, USA; 2Department of Ophthalmology, Jules Stein Eye Institute, UCLA, Los Angeles, CA, USAPurpose: To describe clinical ...
Amir Pirouzian, Joseph L Demer
doaj +1 more source
Ocular biometric changes after Ahmed glaucoma valve implantation
Purpose: To investigate the ocular biometric changes after uneventful Ahmed glaucoma valve implantation. Methods: Patients with refractory glaucoma who were candidate for Ahmed valve surgery were prospectively included in this study.
Arezoo Miraftabi +2 more
exaly +1 more source
Efficacy and safety outcomes of the Paul glaucoma implant compared to the Ahmed glaucoma valve [PDF]
This study compares the one-year outcomes of standalone Ahmed glaucoma valve (AGV) implantation and standalone Paul glaucoma implant (PGI) in adult patients with primary and secondary glaucoma.
Angi Lizbeth Mendoza-Moreira +7 more
doaj +2 more sources