Results 21 to 30 of about 18,925 (253)

Experimental study on lateral displacement measurement using air-coupled ultrasound transducers

open access: yesMechanical Engineering Journal, 2014
We propose a novel measurement method for directly measuring the lateral displacement of structures by using air-coupled ultrasound transducers. The normally-distributed far field of an ultrasound transducer in a lateral direction is taken advantage of ...
Iwao MATSUYA   +2 more
doaj   +1 more source

Air-coupled ultrasound inspection of glued laminated timber [PDF]

open access: yesHolzforschung, 2011
Abstract A novel air-coupled ultrasound (ACU) 120 kHz normal transmission system enabled successful imaging of bonding and saw cut defects in multilayered glulam beams up to 280 mm in height with a signal-to-noise ratio (SNR) of 40 dB. The main wave propagation paths were modeled; quasi-longitudinal and quasi-transverse modes were coupled ...
Sanabria, Sergio J.   +4 more
openaire   +2 more sources

Air-Coupled Piezoelectric Transducers with Active Polypropylene Foam Matching Layers

open access: yesSensors, 2013
This work presents the design, construction and characterization of air-coupled piezoelectric transducers using 1–3 connectivity piezocomposite disks with a stack of matching layers being the outer one an active quarter wavelength layer made of ...
Tomás E. Gómez Alvarez-Arenas
doaj   +1 more source

Application of Micro-Electro-Mechanical Sensors Contactless NDT of Concrete Structures

open access: yesSensors, 2015
The utility of micro-electro-mechanical sensors (MEMS) for application in air-coupled (contactless or noncontact) sensing to concrete nondestructive testing (NDT) is studied in this paper.
Suyun Ham, John S. Popovics
doaj   +1 more source

An Integrated Front-end Circuit Board for Air-Coupled CMUT Burst-Echo Imaging

open access: yesSensors, 2020
To conduct burst-echo imaging with air-coupled capacitive micromachined ultrasonic transducers (CMUTs) using the same elements in transmission and reception, this work proposes a dedicated and integrated front-end circuit board design to build an imaging
Lei Ye   +4 more
doaj   +1 more source

Deep-Subwavelength-Optimized Holey-Structured Metamaterial Lens for Nonlinear Air-Coupled Ultrasonic Imaging

open access: yesSensors, 2021
Ultrasound non-destructive testing (NDT) is a common technique used for defect detection in different materials, from aluminium to carbon-fiber-reinforced polymers (CFRPs).
Marco Boccaccio   +4 more
doaj   +1 more source

Air-Coupled and Resonant Pulse-Echo Ultrasonic Technique

open access: yesSensors, 2019
An ultrasonic, resonant, pulse-echo, and air-coupled nondestructive testing (NDT) technique is presented. It is intended for components, with regular geometries where it is possible to excite resonant modes, made of materials that have a high acoustic ...
Tomás Gómez Álvarez-Arenas   +1 more
doaj   +1 more source

Mass Transfer Study on Drying of Curdlan by Hot Air Coupled with Ultrasound and Infrared Irradiation and Quality Analysis

open access: yesShipin gongye ke-ji
Objective: Hot air coupled with ultrasound and infrared irradiation were used for the drying of curdlan. The drying mechanism and quality change of curdlan were explored under the multi-physical fields, so as to developing the green drying technology of ...
Hongqian WANG   +6 more
doaj   +1 more source

CFRP pipe inspection by means of air-coupled ultrasound [PDF]

open access: yesAIP Conference Proceedings, 2019
Due to their high strength and stiffness at comparatively low weight, lightweight construction materials such as fiber reinforced plastics (FRP) are used in a variety of technical systems. The areas of application range from aerospace and renewable energies to the automotive sector, which is gaining increasing importance.
Sebastian Joas   +3 more
openaire   +1 more source

A Study of a Parametric Method for the Snow Reflection Coefficient Estimation Using Air-Coupled Ultrasonic Waves

open access: yesSensors, 2020
In this paper, a method for estimating snow pressure reflection coefficient based on non-contact ultrasound examination is described. A constant frequency and air-coupled ultrasound pulses were used in this study, which incorporates a parametric method ...
Krzysztof Herman   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy