Results 161 to 170 of about 8,576 (208)
Intra-operative fluoroscopy exposure in endoscopic lumbar discectomies. [PDF]
Tsipouriaris P +7 more
europepmc +1 more source
A Theoretical Study of Measuring In-Air Collision Kerma
openaire
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Air kerma rate constants for radionuclides
European Journal of Nuclear Medicine, 1988Conversion to SI units requires that the exposure rate constant which was usually quoted in R.h-1.mCi-1.cm2 be replaced by the air kerma rate constant with units m2.Gy.Bq-1.s-1. The conversion factor is derived and air kerma rate constants for 30 radionuclides used in nuclear medicine and brachytherapy are listed.
Wasserman H., Groenewald W.
openaire +4 more sources
Spectra and air-kerma strength for encapsulated 192Ir sources
Medical Physics, 1999The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of four types of encapsulated sources ...
Borg, J., Rogers, D. W.O.
openaire +5 more sources
Development and characterization of air kerma cavity standard
Measurement, 2019Abstract Ionization chambers are the most common detectors for precise measurements such as these required in radiation protection and radiotherapy. This paper presents the design, development and characterization of a new graphite-walled cavity ionization chamber used as a primary standard for air kerma rate for 137Cs and 60Co gamma radiation of the
M.M. Szymko +3 more
openaire +3 more sources
Calculation of air-kerma rate of diagnostic X-ray generators
Radiological Physics and Technology, 2010As one type of basic physical data related to the calculation of the construction of X-ray examination room shielding, we investigated the air-kerma rate 1 m from the source of the useful beam focus per unit current time product. Compared to the X-ray energy penetration values obtained in prior research, we obtained higher values. We found three causes
Yoh, Katoh +5 more
openaire +4 more sources
Lowering air kerma to improve the CTO operator's karma
Catheterization and Cardiovascular Interventions, 2023Key Points Along with the implementation of protection devices and procedural techniques, optimizing fluoroscopic protocols is a crucial step to reduce radiation dose to cath‐lab operators According to this retrospective study, using an ultra‐low dose fluoroscopy protocol (3.75 frames per second) is a simple, effective, and safe way to reduce radiation
Stefano Rigattieri, Matteo Casenghi
openaire +2 more sources

