Analysis on cold state test of 300MW circulating fluidized bed boiler
A cold state test was performed on a 300MW circulating fluidized bed boiler. It mainly includes: calibration of air volume measuring device, uniformity test of secondary air nozzle and characteristics of lower secondary air baffle, resistance test of air
Guanhua Xiao, Yan Xi
doaj +1 more source
Design of variable frequency control system for local ventilator based on fuzzy theory
The existing variable frequency control method for local ventilator lacks prediction of gas outburst variable. When a large amount of gas emission abnormally, there is a certain lag in regulation, which is easy to lead to gas accumulation.
JIA Tianyi +3 more
doaj +1 more source
Penentuan penambahan volume air konstan pada pengomposan sampah daun dilakukan untuk mendapatkan volume air optimum selama 1 siklus. Penambahan secara manual pada proses pengomposan dapat menyebabkan hambatan proses dekomposisi materi, ketidakpraktisan ...
Ganjar Samudro +4 more
doaj +1 more source
BEJANA UKUR STANDAR DENGAN TAMPILAN DIGITAL MENGGUNAKAN SENSOR KAPASITIF BERBASIS ARDUINO NANO
Pada saat ini, bejana ukur standar hanya terdapat yang manual, yakni dengan menggunakan jangka sorong. Namun, salah satu kekurangannya disebabkan oleh human error. Oleh karena itu, dilakukan penelitian membuat bejana ukur standar dengan tampilan digital.
Mas Ninda Pertiwi, Galih Setyawan
doaj +1 more source
RANCANG BANGUN KULKAS MINI PORTABLE MENGGUNAKAN PELTIER
Pendinginan dengan peltier thermo electric cooler menggunakan modul TEC-12706 untuk mengetahui temperatur yang dicapai pada media dan memberikan inovasi baru dari modul peltier guna mengurangi komponen pada pendinginan konvensial pada umumnya.
Aris Suryadi, Achmad Firmansyah
doaj +1 more source
Optimization and transformation of ventilation system in Jining No.2 Coal Mine
Currently, there's a lack of research on air volume regulation and mine resistance reduction of ventilation system in mine working face. In order to solve the above problem, taking 10303 working face and 33low 02 working face of Jining No.2 Coal Mine as ...
ZHANG Yiran +4 more
doaj +1 more source
Analysis on air volume balance and resistance characteristics of central exhaust system in tunnel [PDF]
With the increase of tunnel length, the air volume imbalance among the outlets for the central exhaust system is serious. Which causes the actual air volume of the end outlet is small.
Gan Lu, Wang Hao
doaj +1 more source
THE COEFFICIENT OF EXPANSION OF AIR AT CONSTANT VOLUME [PDF]
n ...
openaire +2 more sources
Research on grading control of mine ventilation system
In view of problem that present mine ventilation system control had not been considered from overall perspective of ventilation system, a grading control method of mine ventilation system was proposed based on structure of mine ventilation system and air
WEI Yinshang +3 more
doaj +1 more source
Construction and application of intelligent ventilation system in Hulusu Coal Mine
Aiming at the problems of poor real-time ventilation monitoring, lack of remote regulation of ventilation facilities, complex and inefficient air volume regulation process in Hulusu Coal Mine, in order to realize the controllability, visualization and ...
GUO Weizhou +7 more
doaj +1 more source