Results 171 to 180 of about 1,551,125 (243)

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós   +11 more
wiley   +1 more source

JACMP 2005–2009

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Timothy D. Solberg
wiley   +1 more source

From 2D to 3D gamma passing rate tolerance and action limits for patient‐specific quality assurance in volumetric‐modulated arc therapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Volumetric modulated arc therapy (VMAT) requires an accurate patient‐specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ‐index and the two‐dimensional gamma passing rate (2D %GP). A three‐dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose ...
Christos Zarros   +6 more
wiley   +1 more source

JACMP 2020–2024

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Susan L. Richardson
wiley   +1 more source

Evaluation of daily residual pancreatic tumor motion for deep‐inspiration breath‐hold radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Breath‐hold techniques are widely used in radiation therapy to minimize respiratory‐induced tumor or organ‐at‐risk motion. However, residual motion persists, necessitating a reliable daily evaluation method. Methods At our institution, fiducial markers serve as surrogates for target localization in pancreatic cancer treatment.
Weihua Mao   +4 more
wiley   +1 more source

Does dose calculation algorithm affect the dosimetric accuracy of synthetic CT for MR‐only radiotherapy planning in brain tumors?

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study compares the dosimetric accuracy of deep‐learning‐based MR synthetic CT (sCT) in brain radiotherapy between the Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB). Additionally, it proposes a novel metric to predict the dosimetric accuracy of sCT for individual post‐surgical brain cases.
Jeffrey C. F. Lui   +3 more
wiley   +1 more source

T2‐weighted imaging of rectal cancer using a 3D fast spin echo sequence with and without deep learning reconstruction: A reader study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To compare image quality and clinical utility of a T2‐weighted (T2W) 3‐dimensional (3D) fast spin echo (FSE) sequence using deep learning reconstruction (DLR) versus conventional reconstruction for rectal magnetic resonance imaging (MRI).
Dan Nguyen   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy