Results 221 to 230 of about 27,496 (250)
Some of the next articles are maybe not open access.

A comparison of ambient dose equivalent meters and dose calculations at constant flight conditions

Radiation Measurements, 2007
Ambient dose-equivalent results from an in-flight comparison between different tissue-equivalent proportional counters and silicon diode spectrometers from seven European institutes are presented a ...
J. Lillhök   +11 more
openaire   +1 more source

Analysis of the relationship between ambient dose, ambient dose equivalent and effective dose in operational neutron spectra

Radiation Protection Dosimetry
Abstract This study examines the relationship between ambient dose H*, ambient dose equivalent H*(10), and effective dose E for external neutron irradiation over 163 operational spectra from different workplaces. The results show that H* provides a reasonable estimate with a controlled margin, even if overestimated, to assess E compared ...
openaire   +2 more sources

Ambient Dose Equivalent, Deep Dose Equivalent Index, and ICRU Sphere Depth-Dose Calculations for Neutrons from 30 to 180 MeV

Radiation Protection Dosimetry, 1994
Detailed depth-dose calculations were performed in the ICRU sphere for monoenergetic parallel neutron beams with energies ranging from 30 MeV to 180 MeV. Fluence-to-dose conversion coefficients were obtained for both absorbed dose and dose equivalent quantities.
B.K. Nabelssi, N.E. Hertel
openaire   +1 more source

The Influence of Radon (Gas and Progeny) and Weather Conditions on Ambient Dose Equivalent Rate

Radiation Protection Dosimetry, 2016
The purpose of this study is to identify the influence of radon (gas and progeny) on the ambient dose equivalent rate measured at the reference station ESMERALDA, where continuous measurements of the ambient dose equivalent rate (every 10 min) combined with activity concentration measurements of radon gas and radon progeny as well as meteorological ...
J L, Márquez   +5 more
openaire   +2 more sources

Measurement of neutron ambient dose equivalent in passive carbon‐ion and proton radiotherapies

Medical Physics, 2008
Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon‐ion and proton radiotherapies were measured using a rem meter, WENDI‐II at two carbon‐ion radiotherapy facilities and four proton radiotherapy facilities in Japan.
Shunsuke, Yonai   +11 more
openaire   +2 more sources

Monte Carlo study of neutron-ambient dose equivalent to patient in treatment room

Applied Radiation and Isotopes, 2016
This paper presents an analytical method for the calculation of the neutron ambient dose equivalent H* (10) regarding patients, whereby the different concrete types that are used in the surrounding walls of the treatment room are considered. This work has been performed according to a detailed simulation of the Varian 2300C/D linear accelerator head ...
A, Mohammadi   +4 more
openaire   +2 more sources

State primary standard of units of absorbed dose, absorbed dose rate, ambient and individual dose equivalents, rates of ambient and individual dose equivalents of neutron radiation GET 117-2023

Izmeritel`naya Tekhnika
The issues related to ensuring the uniformity of measurements and traceability of measurement results obtained using clinical dosimeters in neutron radiation therapy are considered in relation to the State Primary Standard of units of absorbed dose, absorbed dose rate, ambient and individual dose equivalents, ambient and individual dose equivalent ...
S. G. Fedorov   +4 more
openaire   +1 more source

The Measurement of Practical Radiation Fields and Calculation of Ambient and Effective Dose Equivalent

Radiation Protection Dosimetry, 1989
Abstract A method was developed for the characterisation of photon radiation fields using collimated filtered Geiger-M¨ller detectors. With information produced by this equipment, calculations were made of the various monitoring quantities, HE, H*(10) and Hp(10), for a range of typical radiation environments.
P.H. Burgess   +2 more
openaire   +1 more source

Ambient dose rate equivalent in Kopački rit and its surroundings

2019
Mjerenja ambijentalnog doznog ekvivalenta (H* (10)) gama zračenja u Kopačkom ritu provedena su u sklopu zajedničkog projekta Instituta za medicinska istraživanja i medicinu rada iz Zagreba i Odjela za fiziku Sveučilišta u Osijeku pod nazivom ''Radiološka karakterizacija Kopačkog rita''.
Petrinec, Branko   +7 more
openaire  

Calculations for ambient dose equivalent rates in nine forests in eastern Japan from 134Cs and 137Cs radioactivity measurements

Journal of Environmental Radioactivity, 2021
Satoru Miura   +2 more
exaly  

Home - About - Disclaimer - Privacy