Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”

open access: yesРадиационная гигиена, 2021
If the neutron fields at personnel workplaces differ from the neutron fields in which individual dosimeters are verified, there is a possibility of additional errors in the assessment of such dosimetric quantities as ambient dose equivalent, individual ...
M. D. Pyshkina   +7 more
doaj   +1 more source

Range-shifter effects on the stray field in proton therapy measured with the variance–covariance method

open access: yesFrontiers in Oncology, 2022
Measurements in the stray radiation field from a proton therapy pencil beam at energies 70 and 146 MeV were performed using microdosimetric tissue-equivalent proportional counters (TEPCs).
Linda Eliasson   +5 more
doaj   +1 more source

Model for Reconstruction of γ-Background during Liquid Atmospheric Precipitation

open access: yesMathematics, 2021
With regard to reconstructing the gamma background dose rate, existing models are either empirical with limited applicability or have many unknown input parameters, which complicates their application in practice.
Valentina Yakovleva   +4 more
doaj   +1 more source

Characterization of the Secondary Neutron Field Produced in a Thick Aluminum Shield by 1 GeV/u 56Fe Ions Using TLD-Based Ambient Dosimeters

open access: yesFrontiers in Physics, 2020
The neutron ambient dose equivalent induced by galactic cosmic-ray-like (1 GeV/u 56Fe) radiation stopped in a thick aluminum shield was measured at different angles with a GSI neutron ball, the standard TLD (thermoluminescent dosimeters)-based neutron ...
Daria Boscolo   +15 more
doaj   +1 more source

214Bi/214Pb radioactivity ratio three-year monitoring in rainwater in Prague

open access: yesNukleonika, 2020
Continuous monitoring of natural gamma radiation in air has been carried out, during December 2014 – January 2018, with 1-min cyclic measurement in Prague, Czech Republic using a NaI(Tl) probe.
Ambrosino Fabrizio   +3 more
doaj   +1 more source

Ambient dose equivalent rate and soil contamination density with 137Cs in kitchen gardens in settlements of the Bryansk region, Russia in 2020–2021

open access: yesРадиационная гигиена, 2021
The article provides results of application of the field (in situ) gamma spectrometry method for carrying out mass monitoring measurements of ambient dose equivalent rate and soil contamination density with 137Cs in kitchen garden plots located in the ...
V. P. Ramzaev   +2 more
doaj   +1 more source

Neutron spectrometry at low fluence rates for radiation protection at the AMANDE facility [PDF]

open access: yesEPJ Web of Conferences, 2020
A neutron spectrometry campaign was carried out in the AMANDE accelerator control room. These measurements had several objectives, one of which was to verify the possibility of determining, with the HERMEIS Bonner sphere system, very low fluence and ...
Lacoste V., Petit M., Gressier V.
doaj   +1 more source

Total Ambient Dose Equivalent Buildup Factors for Portland Concrete

open access: yesHealth Physics, 2018
Abstract In this work, total ambient dose equivalent buildup factors for Portland concrete slabs are calculated using Monte Carlo n-particle software MCNP6™. Buildup factor calculations could approach intractable solutions in general as they depend on a large number of variables.
Dučkić, Paulina, Hayes, Robert Bruce
openaire   +2 more sources

Assessment of annual effective dose from external exposure in forests of the south-western districts of the Bryansk region of Russia: 2015–2021

open access: yesРадиационная гигиена, 2022
During a stay in a radioactively contaminated forest, a person is inevitably exposed to ionizing radiation from the man-made radionuclides. The purpose of this study was to evaluate the external component of the annual effective dose due to exposure in ...
V. P. Ramzaev   +4 more
doaj   +1 more source

Monte Carlo Simulation of H*(10)/Kα Conversion Coefficients of 15 keV~1.5 MeV Single Energy Photons and Narrow Spectrum Series

open access: yesJournal of Isotopes, 2022
Ambient dose equivalent is the calibration quantity and type inspection quantity of environmental and workplace radiation monitoring instrument. The conversion coefficient from air kerma to ambient dose equivalent recommended in ISO 4037-2 is suitable ...
XU Yang;GAO Fei;ZHAO Rui;LIN Min;NI Ning;WEI Kaidi