Results 21 to 30 of about 21,913 (212)
Ambient dose equivalent is the calibration quantity and type inspection quantity of environmental and workplace radiation monitoring instrument. The conversion coefficient from air kerma to ambient dose equivalent recommended in ISO 4037-2 is suitable ...
XU Yang;GAO Fei;ZHAO Rui;LIN Min;NI Ning;WEI Kaidi
doaj
The article presents data on the radiation situation on the territories of the protected zones of peaceful nuclear explosions «Globus-2», «Agat» and «Rubin-1» based on the results of field studies in 2020.
E. V. Khramtsov +4 more
doaj +1 more source
Correlation analysis of gamma dose rate from natural radiation in the test field [PDF]
This paper deals with correlation analysis of gamma dose rate measured in the test field with the five distinctive soil samples from a few minefields in Federation of Bosnia and Herzegovina.
Avdic Senada +3 more
doaj +1 more source
Because of the increase in the demand for the calibration of neutron detectors, there is a need for new calibration services. In this context, the Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares (IPEN), São Paulo, which ...
Tallyson Sarmento Alvarenga +4 more
doaj +1 more source
Radiation situation at the “Pirit” peaceful underground nuclear explosion site
The aim of this study was to evaluate radiation situation at the “Pirit” peaceful underground nuclear explosion site. The peaceful underground nuclear explosion “Pirit” with the capacity of 37.6 kt оf TNT equivalent was carried out on May 25, 1981 on the
A. M. Biblin +6 more
doaj +1 more source
The monitoring of neutron ambient dose equivalent rate in a radiation field is of significant importance as it can reflect the operational status of nuclear facilities and provide radiation protection information.
Can CHENG +6 more
doaj +1 more source
The neutron dose equivalent around high energy medical electron linear accelerators [PDF]
The measurement of neutron dose equivalent was made in four dual energy linear accelerator rooms. Two of the rooms were reconstructed after decommissioning of 60Co units, so the main limitation was the space. The measurements were performed by a
Poje Marina +10 more
doaj +1 more source
The provision for the Brazilian Army of equipment that provides reliable and safe measurements, enabling decision-making based on radioprotection parameters, leads to the need to investigate the metrology of the calibration system used in the Radiation ...
Thiago de Medeiros Silveira Silva +6 more
doaj +1 more source
Deep‐UV (258 nm) femtosecond pulses enable uniform amorphous silicon writing on Si(100)/(111) with a six‐fold larger fluence amorphization window than NIR methods. Optimized fluence and overlap yield 20–45 nm uniform and continuous amorphous layers. Microscopy shows sharp interfaces, and real‐time reflectivity reveals nanosecond melt–resolidification ...
Wissal Benali +5 more
wiley +1 more source
The paper presents results of a comprehensive radiation survey conducted in 2019 in six districts of the eastern part of the Orenburg region in 37 settlements with previously found elevated levels of activity concentration of natural radionuclides in tap
T. A. Kormanovskaya +9 more
doaj +1 more source