Results 211 to 220 of about 4,213,461 (261)

Equity at the Intersection of Heart Failure and Interventions: A Review of the Spectrum From Ambulatory Care to Cardiogenic Shock. [PDF]

open access: yesJ Soc Cardiovasc Angiogr Interv
Mutebi C   +10 more
europepmc   +1 more source

Real‐world evaluation of capillary microsampling for drug monitoring of anti‐seizure medications

open access: yesEpilepsia, EarlyView.
Abstract Objective Capillary microsampling offers a minimally invasive alternative to venipuncture for therapeutic drug monitoring (TDM) of anti‐seizure medications (ASMs). We evaluated the feasibility and reliability of volumetric absorptive microsampling (VAMS) and quantitative dried blood spot (qDBS) devices for ambulatory self‐collection and at ...
Chiara Cancellerini   +8 more
wiley   +1 more source

Phenotypic and transcriptomic characterization of biallelic RNU2‐2 developmental and epileptic encephalopathy

open access: yesEpilepsia, EarlyView.
Abstract Objective A significant proportion of individuals with suspected genetic developmental and epileptic encephalopathies (DEEs) remain unsolved following whole genome sequencing (WGS). Here we describe biallelic RNU2‐2 variants causing a recently reported, severe, recessive DEE.
Olivia J. Henry   +23 more
wiley   +1 more source

Patient-Centered Priorities for Older Adults in Ambulatory Care.

open access: yesJAMA Netw Open
Schiltz NK   +7 more
europepmc   +1 more source

How much does the reduced electroencephalographic montage matter for seizure detection? A large‐cohort simulation study

open access: yesEpilepsia, EarlyView.
Abstract Objective Subscalp electroencephalographic (EEG) systems with few channels have emerged as promising solutions for ultra‐long‐term seizure monitoring, but the impact of montage configuration on automated seizure detection is unclear. We compared automated detection performance between full‐scalp and simulated reduced montages approximating ...
Joe Kojima   +8 more
wiley   +1 more source

Spike detection in the wild: Screening of suspected temporal lobe epilepsy cases using a tailored 2‐channel wearable EEG

open access: yesEpilepsia Open, EarlyView.
Abstract Objective To clinically validate the contribution of a custom‐built EEG wearable device (waEEG) compared to a full 10–20 electrode array ambulatory EEG (aEEG) for screening epilepsy cases in patients with suspected temporal lobe epilepsy (TLE) but negative routine EEGs. Methods Patients (aged 16–91 years) with clinically suspected TLE who were
Daniel Filipe Borges   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy