Results 61 to 70 of about 358 (179)

Relaxed Unbalanced Three‐Phase OPF for Operating Envelopes in LV Distribution Grids and Influence of Grid Topology

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This work introduces a relaxed unbalanced three‐phase optimal power flow framework for computing maximum day‐ahead operational envelopes in LV networks. Validation on the IEEE EU LV Testfeeder and 49 real feeders in Brussels demonstrates 7%–10% flexibility gains over fair methods, while a feeder typology analysis highlights the influence of topological
Lionel Delchambre   +2 more
wiley   +1 more source

Multiphysics Simulation Analysis of Submarine Cable Topology Considering Environmental Constraints

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
The article establishes a high‐accuracy electromagnetic‐thermal coupled multiphysics model for predicting the ampacity of submarine cables, with results showing minimal error compared to the IEC standard. It also analyses the loss distribution across cable layers under different conditions and explores the impact of environmental factors like wind ...
Yuyang Zhao   +5 more
wiley   +1 more source

Advanced Hosting Capacity Assessment in Distribution Systems Using a Centralised HIL‐Based Setup

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
The paper proposes a two‐stage framework for assessing distributed energy resource (DER) hosting capacity that combines an initial optimisation‐based estimate with real‐time validation using a centralised IEC 61850–compliant Hardware‐in‐the‐Loop (HIL) platform and a digital twin of the IEEE 33‐bus system.
Meysam Pashaei   +3 more
wiley   +1 more source

Ampacity assessment and enhancement scheme for power cables for HDD installation

open access: yesZhejiang dianli
Directional drilling installation of cables at great depths and spans is a common method for crossing non-excavated areas. However, existing methods for assessing the ampacity of cables installed via horizontal directional drilling (HDD) do not account ...
YU Shangyu   +5 more
doaj   +1 more source

Ampacity Calculation of Three-Core Submarine Export Cables for Offshore Wind Farms

open access: yes南方能源建设
[Objective] Accurate calculation of the ampacity for export cables from offshore wind farms is crucial for their economical and reliable operation. However, the existing IEC 60287 standard lacks a calculation method for the J-tube laying configuration ...
Xi YANG   +5 more
doaj   +1 more source

Impact analysis of DLR systems with forecasting on economic benefits and renewable generation curtailments

open access: yesInternational Journal of Electrical Power & Energy Systems
This article studies the benefits obtained from the use of overhead line dynamic line rating (DLR) systems in the operation and scheduling of the electricity market. The use of these systems makes it easier to operate the network more efficiently in real
Paula Castillo   +3 more
doaj   +1 more source

The effect of PV modules on temperature conditions of nearby power cables

open access: yesFrontiers in Energy Research
The highest permissible load of power cables (ampacity) depends strongly on the ambient temperature, which in the case of cables surrounded by free air is generally assumed to be 25°C.
Stanislaw Czapp   +3 more
doaj   +1 more source

Surge impedance loading aware reactive power management system for offshore oil and gas facilities

open access: yesResults in Engineering
Long HVAC submarine cables inject substantial charging MVARs. They cause the Ferranti effect at the receiving end and also shrink the cable’s ampacity margin. This paper presents a Surge Impedance Loading Aware Reactive Power Management System (SILARPMS)
Wasseem Khardawi, Umer Amir Khan
doaj   +1 more source

Simulation on Temperature and Ampacity of Mining Flame-proof High Voltage Cable Connector

open access: yesMATEC Web of Conferences, 2017
To investigate the accident causes of mining flame-proof high voltage (F-HV) cable connector, the temperature and ampacity of LBG1-200/6 high voltage cable connector are analyzed.
Li Haiying   +2 more
doaj   +1 more source

Transient dynamic ampacity of overhead transmission lines utilizing CIGRE Technical Brochure 601: Application under conditions in the Slovak Republic

open access: yesInternational Journal of Electrical Power & Energy Systems
This paper proposes a methodology for determining the transient dynamic ampacity of overhead transmission line (OHTL) conductors, with subsequent application to both conventional aluminum conductor steel-reinforced (ACSR) and high-temperature low-sag ...
František Margita   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy