Surgical Theater, a Novel Technology, Enhances 3-dimensional Mapping for Robotic-assisted Deep Inferior Epigastric Perforator Free Flap. [PDF]
Lohasammakul S+4 more
europepmc +1 more source
Log file‐based quality assurance method for respiratory gating system
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon+7 more
wiley +1 more source
Evaluation of radiological data for three-dimensonal physical models to assist personalized anesthesia in neuroaxial interventions with difficult anatomy. [PDF]
Cagiran Z+5 more
europepmc +1 more source
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin+5 more
wiley +1 more source
Diagnosing the first patient: Integrating histopathology into an undergraduate gross anatomy course. [PDF]
Robertson KA, Kruskie M, Byram JN.
europepmc +1 more source
Abstract Purpose Sparing pharyngeal constrictor muscles (PCMs) during radiotherapy improves patient‐reported swallowing function. This study aimed to explore the feasibility of integrating knowledge‐based planning (KBP) with multicriteria optimization (MCO) in Eclipse v18.0 to selectively spare PCM, quantify the required trade‐off in prophylactic ...
Laura K. Howard+3 more
wiley +1 more source
Retention of gross and clinical anatomy knowledge among medical graduates in Sudan: a comparative study. [PDF]
Saeed M+7 more
europepmc +1 more source
Developing reference plans for evaluating global clinical trials credentialing and PSQA systems
Abstract Purpose To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.
Fre'Etta M. D. Brooks+13 more
wiley +1 more source
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley+4 more
wiley +1 more source
Comparative evaluation of the utility of two oral examination tools in assessing oral health in stroke patients with indwelling gastric tubes. [PDF]
Tu S+7 more
europepmc +1 more source