Results 51 to 60 of about 133,649 (182)

Finite Element Analysis of Balloon-Expandable Coronary Stent Deployment: Influence of Angioplasty Balloon Configuration [PDF]

open access: yes, 2013
Today, the majority of coronary stents are balloon-expandable and are deployed using a balloon-tipped catheter. To improve deliverability, the membrane of the angioplasty balloon is typically folded about the catheter in a pleated configuration. As such,
Martin, David, Boyle, Fergal
core   +1 more source

Impact of Stepwise Balloon Angioplasty for De Novo Femoropopliteal Artery: A Retrospective Observational Study

open access: yesHealth Science Reports
Background and Aims Drug‐coated balloon use in the revascularisation of femoropopliteal (FP) lesions improves patency rates. However, conventional balloon angioplasty sometimes leads to severe artery dissection, which may be prevented using stepwise ...
Takahiro Tokuda   +8 more
doaj   +1 more source

One‐Year Clinical Outcomes of Paclitaxel‐Coated Balloon Angioplasty in Patients With and Without Acute Coronary Syndrome: The ALLIANCE Registry

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Real‐world data after percutaneous coronary intervention (PCI) using drug‐coated balloons (DCBs) in acute coronary syndrome (ACS) are limited. Aims We compared 1‐year clinical outcomes after PCI with paclitaxel DCBs between the ACS and non‐ACS patients.
Takashi Muramatsu   +18 more
wiley   +1 more source

Angiographic and histologic consequences of laser thermal angioplasty: comparison with balloon angioplasty.

open access: yes, 1987
The angiographic and histologic consequences of laser thermal angioplasty were examined and compared with those of conventional balloon angioplasty in an atherosclerotic rabbit iliac artery preparation immediately and 4 weeks after the procedure ...
C C Haudenschild   +4 more
core   +1 more source

The Triple Wire Dual Angioseal Technique for Large Bore Femoral Access Closure

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT There is a growing need for large‐bore femoral access across cardiac interventions. This has led to a need for more widely accessible vascular closure techniques to facilitate reliable vascular closure and wider access to these interventions.
Hilal Khan, Mohaned Egred
wiley   +1 more source

Excimer Laser Coronary Atherectomy (ELCA) Utilization in Complex PCI: A Position Paper of the Italian Society of Interventional Cardiology (SICI‐GISE)

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Excimer laser coronary atherectomy (ELCA) has significantly influenced interventional cardiology, particularly in complex percutaneous coronary interventions (PCIs). This expert review by the Italian Society of Interventional Cardiology (SICI‐GISE) provides a comprehensive overview of ELCA's applications, mechanisms of action, and clinical ...
Giuseppe M. Sangiorgi   +17 more
wiley   +1 more source

Non-slip element percutaneous transluminal angioplasty balloon (NSE PTA).

open access: yes, 2022
The NSE PTA scoring balloon is a non-slip peripheral angioplasty catheter with three nylon scoring elements for a controlled scoring of the vessel wall and aimed to reduce slipping during balloon inflation.
Masao Takigami (12041910)   +8 more
core   +1 more source

External Validation of the UK‐BCIS CHIP Score to Predict 1‐Year Outcomes in Patients Undergoing IVL‐Assisted PCI: Insights From the International BENELUX‐IVL Registry

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background The United Kingdom–British Cardiovascular Intervention Society complex high‐risk indicated percutaneous coronary intervention (UK‐BCIS CHIP) score was developed to identify patient‐ and procedural factors to predict short‐term adverse outcomes in patients undergoing high risk percutaneous coronary intervention (PCI). The performance
Akshay A. S. Phagu   +18 more
wiley   +1 more source

Balloon dilatation angioplasty: nonsurgical management of coarctation of the aorta.

open access: yes, 1984
Balloon dilatation angioplasty was successfully performed in five patients (ages 18 months to 17 years) with discrete aortic coarctation. The catheter size was No. 8F or 9F.
S B Ritter, R S Cooper, R J Golinko
core   +1 more source

Interventional therapies for chronic heart failure: An overview of recent developments

open access: yesESC Heart Failure, Volume 12, Issue 2, Page 1081-1094, April 2025.
Abstract Heart failure (HF), the final manifestation of most cardiovascular diseases, has become a major global health concern, affecting millions of individuals. Despite basic drug treatments, patients present with high morbidity and mortality rates. However, recent advancements in interventional therapy have shown promising results in improving the ...
Bingchen Guo   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy