Results 141 to 150 of about 692,464 (289)

Fig. 5. Angular rate and acceleration of EOTS MEMS IMU

open access: yes
Angular rate and acceleration of EOTS MEMS ...
Sang Heon Oh (18475512)   +2 more
core   +1 more source

Optoelectronic Synaptic Devices Using Molecular Telluride Phase‐Change Inks for Three‐Factor Learning

open access: yesAdvanced Functional Materials, EarlyView.
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner   +14 more
wiley   +1 more source

Robust Electrocaloric Performance Enabled by Highly‐Polar Frustrated Nanodomains in NaNbO3‐Based Ferrodistortive Relaxor

open access: yesAdvanced Functional Materials, EarlyView.
P4bm framework in NaNbO3‐Ba(Ti, Hf)O3 ferrodistortive relaxor entails short‐range and highly‐polar ferrodistortive orders. The abundant highly‐polar orders facilitate to increase entropy change, and robust octahedral oxygen tilt enables to impede thermal perturbations.
Feng Li   +11 more
wiley   +1 more source

Self‐Sintering Ionogel Binder for Flexible, Recyclable, and Healable Printed Giant Magnetoresistive Sensors

open access: yesAdvanced Functional Materials, EarlyView.
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo   +10 more
wiley   +1 more source

Regulated Ion‐Diffusion Hydrogels for Subtle and Multimodal Temperature‐Strain Sensing in Wound Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang   +7 more
wiley   +1 more source

MEMS angular rate and angular acceleration sensors with CMOS switched capacitor signal conditioning.

open access: yes, 2004
Microelectromechanical sensors were designed to measure angular rate and angular acceleration signals. Sensors were fabricated in micromachined polysilicon and silicon on insulator (SOI) structural films using semiconductor wafer fabrication equipment ...
O'Brien, Gary J.
core   +1 more source

An Angular Acceleration Based Looming Detector for Moving UAVs. [PDF]

open access: yesBiomimetics (Basel)
Zhao J, Xie Q, Shuang F, Yue S.
europepmc   +1 more source

Home - About - Disclaimer - Privacy