Results 81 to 90 of about 176,662 (294)

Stripping Voltammetric Determination Of Zinc, Cadmium, Lead And Copper In Blood Samples Of Children Aged Between 3 Months And 6 years [PDF]

open access: yes, 2005
Blood samples of 160 children, ranging age between 3 months and 6 years were selected from five different parts of Amritsar district of Punjab (India) and were analyzed for Zn, Cd, Pb and Cu using anodic stripping voltammetry.
Rakesh Kumar Mahajan   +5 more
core  

Anodic stripping voltammetry at hydrodynamic mercury thin film electrodes. Numerical simulation of stripping peaks for reversible processes at uniformly accessible electrodes

open access: yes, 1997
The time dependent backwards implicit method is used to simulate the shape and position of the stripping peaks in DC (linear scan) anodic stripping voltammetry at mercury thin film hydrodynamic electrodes for electrochemically reversible systems.
Compton, RG, Ball, JC, Compton, Richard
core   +1 more source

Electropolymerized Aptasensor for Femtogram‐Level Cytokine Detection

open access: yesAdvanced Materials, EarlyView.
Electropolymerization of 3‐amino‐ʟ‐tyrosine creates ultrathin, smooth, and chemically robust pALT nanofilms with accessible carboxyl functionalities for direct aptamer immobilization. Integrated with fiber‐optic SPR and OECT platforms, these interfaces enable IL‐6 detection down to 100 fg mL−1 and provide a versatile route to bioelectronic sensing ...
Jiyao Yu   +7 more
wiley   +1 more source

Análise de especiação de cobre e zinco empregando voltametria de redissolução anódica com pulso diferencial

open access: yesQuímica Nova, 2012
This work describes methodologies for speciation analysis of the metals copper and zinc as total, total dissolved, labile, as well as complexation capacity (conditional stability constants and available ligand concentration), using the same technique ...
Alessandra Emanuele Tonietto   +1 more
doaj   +1 more source

anodic stripping voltammetry

open access: yes
Citation: 'anodic stripping voltammetry' in the IUPAC Compendium of Chemical Terminology, 5th ed.; International Union of Pure and Applied Chemistry; 2025. Online version 5.0.0, 2025. 10.1351/goldbook.09152 • License: The IUPAC Gold Book is licensed under Creative Commons Attribution-ShareAlike CC BY-SA 4.0 International for ...
openaire   +1 more source

Electrolyte Engineering Challenges and Opportunities for Next‐Generation Aqueous Ammonium‐Ion Batteries

open access: yesAdvanced Materials, EarlyView.
Aqueous ammonium‐ion batteries (AAIBs) face a hydrogen‐bond paradox: the HB network enables fast NH4+ transport but triggers water decomposition. This review dissects this dilemma, evaluates multiple electrolyte engineering strategies, and outlines four future directions for next‐generation AAIB design ABSTRACT Aqueous ammonium‐ion batteries (AAIBs ...
Zi‐Hang Huang   +6 more
wiley   +1 more source

Beads Based Electrochemical Assay for Detection of Hemagglutinin Labeled by Two Different Types of Cadmium Quantum Dots

open access: yesInternational Journal of Electrochemical Science, 2014
In this study it is described beads based isolation assay terminated by electrochemical analysis of hemagglutinin (HA) using two different cadmium quantum dots (QDs) labelled as CdS and CdTe.
Ludmila Krejcova   +11 more
doaj   +1 more source

Determination of Lead in Blood and Urine by Anodic Stripping Voltammetry

open access: yesClinical Chemistry, 1973
Abstract An anodic stripping procedure for determining lead in blood and urine was evaluated, and methods of calibration were developed. The technique requires as little as 50 µl of blood or 0.5 ml of urine. Comparisons were made between results obtained by anodic stripping voltammetry, for finger-puncture blood, and by atomic absorption
B, Searle, W, Chan, B, Davidow
openaire   +2 more sources

Determination of Trace Copper in Water Samples by Anodic Stripping Voltammetry at Gold Microelectrode

open access: yes, 2011
The applicability of gold microelectrode of 25 mu m diameter for electrochemical determination of trace copper ions (Cu(2+)) in water samples by anodic stripping voltammetry (ASV) has been demonstrated.
Pan, Dawei   +5 more
core  

Volatile Memristive Devices With Tunable Temporal Dynamics For Event‐Based Sensing

open access: yesAdvanced Materials, EarlyView.
Tunable volatile memristive devices can serve various neural‐inspired tasks that require different time windows of information retention. The ionic‐based volatility of the presented Pt/a‐STO/TaOx/Ta device stack can be reproducibly and controllably tuned in multiple ways.
Dimitrios Spithouris   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy