Results 111 to 120 of about 271,114 (307)
Kesesuaian Hasil Pengukuran Sudut Bilik Mata Depan antara Pentacam dan Ultrasound Biomicroscopy
The assessment of anterior segment, especially the examination of anterior chamber angle, plays an important role in diagnosing and managing glaucoma.
Maulina Zulkarnain +2 more
doaj +1 more source
Four‐point bending tests are conducted in an argon atmosphere on commercial MgO‐C brick grades with and without MgO‐C recyclate from room temperature up to 1300 °C. No detrimental effect of the MgO‐C recyclates on bending strength is found. Instead, a decisive influence of the total carbon content is observed, with lower total carbon contents ...
Alexander Schramm +5 more
wiley +1 more source
Steven M Silverstein,1 Mitchell A Jackson,2 Damien F Goldberg,3 Mauricio Muñoz4On behalf of the Bromfenac Ophthalmic Solution 0.07% Once Daily Study Group1Silverstein Eye Centers, Kansas City, MO, USA; 2Jacksoneye, Inc., Lake Villa, IL, USA ...
Silverstein SM +3 more
doaj
This study investigates thermo‐chemical processes during high‐temperature testing of two commercial MgO‐C brick grades, one containing 47.5 wt.% MgO‐C recyclate. Using ETV, DTA/TG‐MS, XRD, and SEM/EDS/EBSD, mechanisms such as carbothermal reduction of magnesia, impurity incorporation into the secondary MgO surface layer, and calcium‐rich phase ...
Alexander Schramm +6 more
wiley +1 more source
Non-invasive glucose monitor [PDF]
A non-invasive method for determining blood level of an analyte of interest, such as glucose, comprises: generating an excitation laser beam (e.g., at a wavelength of 700 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of
Borchert, Mark S., Lambert, James L.
core +1 more source
Removing Oxide Layers and Retaining Oxide‐Free Steel Surfaces by Polishing in Oxygen‐Free Atmosphere
In this study, the efficacy of wet mechanical polishing under an oxygen‐free atmosphere for deoxidation and the retention of an oxide‐free steel surface are elucidated using X‐ray photoelectron spectroscopy. The methodology proved successful; however, the results were highly dependent on the preparation of the solvents used to clean the samples after ...
Friedrich Bürger +2 more
wiley +1 more source
Traumatic Hyphema: A Review of Experience at the Medical College of Virginia During the Past Decade [PDF]
Hyphema (hemorrhage into the anterior chamber of the eye), as the result of blunt injury to the eye, carries a potential danger of visual loss if not properly treated.
Geeraets, Walter J. +2 more
core +1 more source
Influence of an Oxygen‐Free Atmosphere on Diamond‐Single‐Grain Scratching of Ti–6Al–4V
Single‐grain scratching of Ti–6Al–4V is investigated under controlled, oxygen‐free, and ambient atmospheres using a novel experimental setup with in situ high‐speed imaging. The approach enables direct observation of chip formation and adhesion under suppressed oxidation.
Berend Denkena +2 more
wiley +1 more source
Aim. To assess the effects of mydriatics commonly used in clinical practice on choroidal thickness and anterior chamber change. Methods. This was a prospective, randomized, controlled, double-blinded study including a single eye of the participants.
İsa Yuvacı +7 more
doaj +1 more source
This study investigates laser‐based oxide removal of Cu inserts in oxygen‐free conditions and examines long‐term oxidation kinetics and surface chemistry under different atmospheres via X‐ray photoelectron spectroscopy. Al–Cu compound casting with differently oxidized surfaces is performed, and intermetallic phase formation, morphology, and thermal ...
Timon Steinhoff +9 more
wiley +1 more source

