Results 11 to 20 of about 3,117,501 (211)

Agreement of Corneal Diameter and Anterior Chamber Depth Measurements with the IOLMaster 500 and the IOLMaster 700 Optical Biometers in Myopic Eyes

open access: yesClinical Ophthalmology, 2023
Purpose To assess the agreement in automated corneal diameter (CD) and anterior chamber depth (ACD, measured from corneal epithelium to lens) distances measurements between the IOLMaster 500 and 700 optical biometers in myopic eyes.
Pedro Tañá-Rivero   +4 more
semanticscholar   +2 more sources

Anterior chamber depth measurement in teenagers. Comparison of two techniques [PDF]

open access: yesJournal of Optometry, 2013
Purpose: The aim of this study is to determine the anterior chamber depth (ACD) in teenagers using two different devices: partial coherence interferometry IOLMaster (Carl Zeiss Meditec) and anterior segment optical coherence tomography (Visante™ OCT ...
Inmaculada Bueno-Gimeno   +4 more
doaj   +2 more sources

Effect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with Cataract [PDF]

open access: yesTürk Oftalmoloji Dergisi, 2011
Purpose: To evaluate the effect of preoperative anterior chamber depth (ACD) on intraocular pressure (IOP) after uneventful phacoemulsification and intraocular lens (IOL) implantation in nonglaucomatous eyes. Material and Method: The medical records of
Tansu Gönen   +4 more
doaj   +2 more sources

Digital slit lamp derived parameters in shallow anterior chamber screening

open access: yesScientific Reports
To evaluate anterior chamber depth (ACD) using diffraction parameters derived from slit-lamp anterior segment (AS) images and assess their diagnostic efficacy in identifying optimal cutoff values for shallow ACD screening.
Jiahui Zhao   +10 more
doaj   +2 more sources

Impact of Pseudoexfoliative Syndrome on Effective Lens Position, Anterior Chamber Depth Changes, and Visual Outcome After Cataract Surgery

open access: yesClinical Ophthalmology, 2021
Michael Müller, Katarzyna Pawlowicz, Myriam Böhm, Eva Hemkeppler, Christoph Lwowski, Lisa Hinzelmann, Mehdi Shajari, Thomas Kohnen Department of Ophthalmology, Goethe-University, Frankfurt, GermanyCorrespondence: Thomas KohnenDepartment of Ophthalmology,
Müller M   +7 more
doaj   +2 more sources

Peripheral anterior chamber depth and screening techniques for primary angle closure disease in community elderly Chinese

open access: yesBMC Ophthalmology, 2020
Background To investigate the distribution of peripheral anterior chamber depth (ACD) and the relationship between peripheral ACD and gonioscopy compared to other ocular parameters for primary angle closure disease (PACD) screening.
Qin Luo   +8 more
doaj   +2 more sources

Measurements of white-to-white corneal diameter and anterior chamber parameters using the Pentacam AXL wave and their correlations in the adult Saudi population [PDF]

open access: yesPeerJ
Background Assessment of eye parameters such as the white-to-white (WTW) corneal diameter, anterior chamber depth (ACD), and anterior chamber angle (ACA) are essential for preoperative evaluation of refractive surgery and diagnosing and managing some ...
Wafa M. Alotaibi   +3 more
doaj   +3 more sources

Correlation between axial length and anterior chamber depth in short eyes, normal eyes, and long eyes

open access: yesJournal of the Egyptian Ophthalmological Society, 2019
Context Accurate intraocular lens (IOL) power calculation is mandatory to achieve satisfactory refractive outcomes. Axial length, keratometric readings, anterior chamber depth, and other measurements are utilized to estimate postoperative effective lens ...
Rafik M.F El-Ghazawy   +3 more
doaj   +2 more sources

Vault-Correlated Efficacy and Safety of Implantable Collamer Lens V4c Implantation for Myopia in Patients with Shallow Anterior Chamber Depth

open access: yesOphthalmic Research, 2023
Introduction: The aim of the study was to evaluate efficacy and safety outcomes after implantation of the Visian Implantable Collamer Lens (ICL V4c) in myopia patients with shallow anterior chamber depth (ACD).
Tian-Wei Qian   +6 more
semanticscholar   +1 more source

Relationship between the main components of the crystalline lens and the anterior chamber depth after cataract formation

open access: yesGraefe's Archive for Clinical and Experimental Ophthalmology, 2023
Purpose To assess the relationship between anterior chamber depth (ACD) and lens thickness (LT), as well as its three main components (anterior and posterior cortex and nucleus thickness), in cataractous and non-cataractous eyes, depending on the axial ...
C. Díez-Montero   +3 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy