Redefined Formula for Anterior Chamber Volume Calculation: Quantitative Analysis of Biometric Parameters Across Ocular Pathologies. [PDF]
Arturs Zemitis,1,2 Vincenzo Rizzuto,1– 4 Diana Lavrinovica,1,2 Juris Vanags,1,2 Guna Laganovska1,2 1Riga Stradins University, Department of Ophthalmology, Riga, Latvia; 2Pauls Stradins Clinical University Hospital, Clinic of Ophthalmology, Riga, Latvia ...
Zemitis A +4 more
europepmc +2 more sources
Age-related changes in corneal parameters in the Turkish population: a Pentacam-based study [PDF]
Purpose To evaluate anterior and posterior corneal surfaces and anterior segment parameters in the Turkish population using Pentacam, and to analyze age-related changes.
Denizcan Özizmirliler, İsmet Durak
doaj +2 more sources
Evaluation of Cornea and Anterior Chamber with Pentacam in Scleroderma Cases
Purpose: To evaluate the anterior segment structures with Pentacam in scleroderma patients. Materials and Methods: The 34 eyes (study group) of 17 scleroderma patients who attended our clinic were compared with 40 eyes (control group) of age-matched 20
Melis Palamar +3 more
doaj +2 more sources
Evaluation of Anterior Chamber Volume in Cataract Patients with Swept-Source Optical Coherence Tomography [PDF]
Purpose.To evaluate the anterior chamber volume in cataract patients with Swept-Source Optical Coherence Tomography (SS-OCT) and its influencing factors.Methods.Anterior chamber volume of 92 cataract patients was evaluated with SS-OCT in this cross-sectional study. Univariate analyses and multiple linear regression were used to investigate gender, age,
Wenwen He +5 more
openaire +4 more sources
Determination of the Aqueous Humor Volume by Three-Dimensional Mapping of the Anterior Chamber
In this study involving 12 patients planned for routine cataract surgery, we used the topography of the anterior chamber depth and the corneal diameter obtained from Orbscan II<sup>®</sup> data to calculate the aqueous humor volume. Prior to the surgical procedure, a small amount of fluorescein was injected into the anterior chamber and an ...
Anders, Behndig, Klas, Markström
openaire +3 more sources
Aqueous humor inflow rate, a key parameter influencing aqueous humor dynamics, is typically measured by fluorophotometry. Analyzing fluorophotometric data depends, inter alia, on the volume of aqueous humor in the anterior chamber but not the posterior chamber. Previous fluorophotometric studies of the aqueous inflow rate in mice have assumed the ratio
Christa Montgomery +2 more
exaly +3 more sources
Newsletter sent to members of the Huntsville Chamber of ...
Huntsville Chamber of Commerce
core +14 more sources
Minimally invasive, direct, real time measurement of drug concentration in the anterior eye [PDF]
The aim of this study was to evaluate a corneal contact lens which effectively turns the anterior chamber of the eye into a cuvette, enabling the concentration of a drug to be measured using absorption spectroscopy. A hand held contact lens incorporating
Uttamchandani, D.G. +5 more
core +4 more sources
EVALUATION OF ANTERIOR SEGMENT PENTACAM CHANGES BEFORE AND AFTER PHACOEMULSIFICATION VERSUS COMBINED PHACOTRABECULECTOMY IN PRIMARY ANGLE-CLOSURE GLAUCOMA [PDF]
Background: Both Phaco alone and Phaco-trab resulted in changes of the drainage angle, anatomy of the anterior chamber and reduction of intraocular pressure (IOP).
Hamed, M. +3 more
doaj +1 more source
Background To evaluate and compare the changes in intraocular pressure and anterior eye segment biometrics during and after wearing two types of commonly used swimming goggles. Methods In a cross-sectional study, a total of 40 healthy adults aged between
Xu Zhang +3 more
doaj +1 more source

