Transducers convert physical signals into electrical and optical representations, yet each mechanism is bounded by intrinsic trade‐offs across bandwidth, sensitivity, speed, and energy. This review maps transduction mechanisms across physical scale and frequency, showing how heterogeneous integration and multiphysics co‐design transform isolated ...
Aolei Xu +8 more
wiley +1 more source
Multi‐million cycle reliability for liquid metal stretchable electronics is achieved through a continuous cycle of mechanical testing, failure mode and mechanism analysis and implementing subsequent mitigation strategies. ABSTRACT Stretchable electronics that combine mechanical compliance with reliable electrical performance are essential for ...
Lennert Purnal +8 more
wiley +1 more source
Topical Mitomycin-C Chemotherapy in Ocular Surface Squamous Neoplasia [PDF]
Charudutt Kalamkar +3 more
doaj +1 more source
A custom shape memory polymer material selection process relates quantitative application criteria (e.g., compression garment yarns) to material characterization information. The selected materials are manufactured into yarn geometries, which expand the design space by creating structural stress‐strain profiles beyond the nominal material stress‐strain
Michaela Andrews +2 more
wiley +1 more source
Haptic pupillary capture secondary to in-the-bag intraocular lens anterior dislocation. [PDF]
Cucurull-Martí M +2 more
europepmc +1 more source
A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein +2 more
wiley +1 more source
Clinical management of nanophthalmos combined with cataract: a case series. [PDF]
Zhu H +6 more
europepmc +1 more source
This article highlights the development of robust and high‐performance flexible and stretchable biosensors that maintain long‐term functionality and optimal electrical conductivity under mechanical deformation, utilizing sustainable and cost‐effective manufacturing principles.
Mousa H. Aldosari, Ahyeon Koh
wiley +1 more source
Uveitis-Glaucoma-Hyphema Syndrome Secondary to Asymmetric Intraocular Lens (IOL) Haptic Fixation: A Clinical Lesson in Mechanism-Based Diagnosis and Treatment. [PDF]
Bonifazi T, Tanito M.
europepmc +1 more source
Thermo‐Derived Cholesteric Liquid Crystal Elastomer Pattern with Composite Structural Colors
A thermochromic cholesteric liquid crystal (CLC) oligomer was synthesized for the preparation of CLC elastomer (CLCE) films with dual reflection bands. Subsequently, a CLCE pattern with composite structural colors was prepared, which was suitably applied for decoration and anti‐counterfeiting.
Li Zhong, Yi Li, Wei Liu, Yonggang Yang
wiley +1 more source